E-Series Controller locked down with 7-segment 96 code
- Views:
- 1,705
- Visibility:
- Public
- Votes:
- 0
- Category:
- e-series-disk-shelves
- Specialty:
- esg
- Last Updated:
- 11/8/2024, 10:38:38 PM
Applies to
- NetApp E-Series
- NetApp E2800
Issue
Controller locks down with 7-segment code 96 with a non responding console/serial port even after power cycling the system.
Recovery Guru reports:
Failure Entry 3: OFFLINE_CTL-Recovery Failure Type Code: 28
Storage array: array1
Component reporting problem: Controller in bay B
Status: Online
Location: Controller/Drive shelf 0, Controller in bay B