Replication down between DC and DR sites on E-Series
Applies to
NetApp E-series 11.7x
Issue
- Replication between DC and DR sites is reported as “down state.”
- The consistency group remains in “Syncing” state in SANtricity System Manager.
- Replication progress resets to 0%.
- Repeated MEL Events for Communication to remote volume UP/DOWN
- Identified missing iSCSI initiator connection for controller B
B:4/21/26, 7:05:48 PM (19:05:48) 328736 6502 Communication to remote volume up - Volume DR_DC_XXX_ B:4/21/26, 7:05:47 PM (19:05:47) 328735 6502 Communication to remote volume up - Volume Qlik_Volume_XXX_DReplxxxxation B:4/21/26, 7:05:46 PM (19:05:46) 328734 1817 iSCSI communication has been established - iqn.0000.00.com.netapp:2806.7f000000005b4fbf33 B:4/21/26, 7:05:45 PM (19:05:45) 328733 6503 Communication to remote volume down - Volume DR_DC_XX_DATA <--CRITICAL B:4/21/26, 7:05:45 PM (19:05:45) 328732 6503 Communication to remote volume down - Volume Qlik_Volume_XXX_Replxxxxation <--CRITICAL