Issue
- After replacing E2800/EF280 controller in a 11.30.x setup, the replacement controller reboot loops after attempting to auto synchronize (ACS) its SANtricity OS to match the original controller (11.30.x).
- The following messages are logged right before reboot, which indicate the controller is attempting to ACS its firmware:
07/21/22-19:25:11 (tRAID): NOTE: ACS: download manager is idle
07/21/22-19:25:11 (tRAID): NOTE: ACS: autoCodeSync(): Process start. Comm Status: 1
07/21/22-19:25:11 (tRAID): NOTE: ACS m_AltUnifiedACSMode: 0
07/21/22-19:25:11 (tRAID): NOTE: ActiveInfo:ver='08.73.00.00' date='2022-05-16' time='17:34:16'
07/21/22-19:25:11 (tRAID): NOTE: ACS required -sync from Drives:false
07/21/22-19:25:11 (tRAID): NOTE: ACS waiting for image transfer
07/21/22-19:25:16 (tRAID): NOTE: ACS m_UnifiedACSMode: 1 m_AltUnifiedACSMode: 0
07/21/22-19:25:16 (tRAID): NOTE: ACS coordinating with baseOS to allocate buffer
07/21/22-19:25:16 (tRAID): NOTE: ACS processing downgrade - waiting on semaphore
07/21/22-19:25:40 (sntpEventTask): NOTE: sntpEventHandler:SOD not complete; skipping NTP sync.