Skip to main content
NetApp Knowledge Base

Host Multipath Driver Incorrect by host MPIO miss one path

Views:
319
Visibility:
Public
Votes:
0
Category:
e-series-systems
Specialty:
esg
Last Updated:

Applies to

E-series

Issue

  • System reports Host Multipath Driver Incorrect.
  • Host is connected with storage directly.
  • One path is missed in MPIO of host.
  • Current data rate of one FC port is degraded.

Host interface: Fibre
Host Interface Card(HIC): Baseboard
Channel: 1
Port: 0a
Current ID: Not applicable/0xFFFFFFFF
Preferred ID: 4/0xE1
NL-Port ID: 0x000000
Maximum data rate: 16 Gbps
Current data rate: 16 Gbps
Data rate control: Auto
Link status: Up
Topology: Point-to-Point
World-wide port identifier: 20:13:00:a0:xx:xx:xx:xx
World-wide node identifier: 20:02:00:a0:xx:xx:xx:xx
Part type: QL-EP8324 revision 2
Data Assurance (DA) capable: Yes

Host interface: Fibre
Host Interface Card(HIC): Baseboard
Channel: 2
Port: 0b
Current ID: Not applicable/0xFFFFFFFF
Preferred ID: 5/0xE0
NL-Port ID: 0x000000
Maximum data rate: 16 Gbps
Current data rate: 8 Gbps
Data rate control: Auto
Link status: Up
Topology: Point-to-Point
World-wide port identifier: 20:23:00:a0:xx:xx:xx:xx
World-wide node identifier: 20:02:00:a0:xx:xx:xx:xx
Part type: QL-EP8324 revision 2
Data Assurance (DA) capable: Yes

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.