E-Series E2700 booting up only after pressing C on console if the system was powered off previously
Applies to
- E-Series E2700
- SANtricity 8.40.60.04
Issue
- E-Series E2700 is not booting automatically after it has been powered off,it is necessary to press C on the console :
7205 QLOGIC EP8324 ISCSI 2
01 Register Read Test Passed
02 Register Address Lines Test Passed
03 Register Data Lines Test Passed
3900 Real-Time Clock
01 RT Clock Tick ** Failed **
*** Error (0005): Real time clock/NVSRAM battery low
STATUS: Real time clock/NVSRAM battery low
*** Current Loop Count: 1 Date: 03/10/2023 Time: 07:27:30
*** Master Error Code: 2701-3900-01-0005
D)isplay R)etry C)ontinue M)onitor S)hell A)bort ?
- System is rebooting automatically if the reboot is done from Santricity