E-Series Volume not on preferred path due to host-side multipath configuration
Applies to
- NetApp E-Series Storage E2860
- SANtricity OS 11.80.1R4
- Fibre Channel environments with Quantum StorNext
- Host multipath configurations using ATTO Celerity FC cards, Linux DM-Multipath, or Windows MPIO
Issue
- Persistent
Volume not on preferred path(VNOPP) events after volume redistribution RECOVERY-GURU-PROCEDURES.HTML:
NON_PREFERRED_PATH-Recovery Failure Type Code: 10
MAJOR-EVENT-LOG:
4011 Volume not on preferred path due to AVT/RDAC failover - Shelf XX, Bay X <--CRITICAL2044 IO shipping implicit volume transfer - Volume VOLNAME - Shipped/Owned IOs: 226026/71683, Host ID: XX
- Issue observed after SANtricity upgrade
- Host-side logs and logs show >75% I/O routed to the alternate controller for affected volumes
- No controller hardware failures, resets, or explicit multipath driver errors detected
- Affected volumes are mapped to clustered hosts with multiple host types (Linux DM-MP, ATTO Cluster, Windows)