E-Series Controller cache battery failed even after applying the latest firmware
- Views:
- 292
- Visibility:
- Public
- Votes:
- 0
- Category:
- e-series-systems
- Specialty:
- esg
- Last Updated:
- 1/28/2025, 10:40:49 AM
Applies to
- NetApp E-Series
- StorageGRID Appliances
- SANtricity OS 11.50.3x or later is installed
- A manual battery learn cycle was recently completed
Issue
- In E-Series AutoSupport bundle (
MAJOR-EVENT-LOG
) or system events, a Controller cache battery failed with:
730f Incomplete battery learn cycle - Shelf XX, Controller X, Bay X - 32C, 7.44V, 8850mAH
210a Controller cache not enabled or was internally disabled - Shelf XX, Bay X - Event: BAD BBU,Controller not Optimal,Battery Unusable-0
3101 Asynchronous event notification (AEN) posted for recently logged event - Shelf XX, Bay X
----> Sense 6/3f/c7 = Unit Attention - Non-media Component Failure
----> FRU group: Subsystem; Tray ID: XX, Type : Nonvolatile Cache, State: Failed
210c Controller cache battery failed - Shelf XX, Controller X, Bay X - 32C, 7.42V, 8850mAH <--CRITICAL
- When AutoSupport is enabled, it will generate an event with:
E-Series Notification from Unnamed (Controller cache battery failed) CRITICAL