Degraded E-Series read latency on flash read cache enabled volume
Applies to
- NetApp E-Series
 - NetApp StorageGRID Appliance (SG6060)
 - Single and Dual controller storage array systems using flash read cache (FRC)
 - SANtricity OS 11.70.4+
 
Issue
- Higher read latency was noticed on flash read cache (FRC) enabled volumes after upgrade to SANtricity OS 11.70.4 or later release.
 - In E-Series support data or controller shell, this command 
tditlnall 3shows the volume (LUN ID) read and write I/O latency. Comparing the latency against pre-11.70.4, the average latency increased from sub-millisecond to multiple milliseconds. 
Pre-11.70.4 SANtricity OS
-> tditlnall 3
Read/Write Completions
.........TDITLN.........:Initiator.:.................R E A D S................:...............W R I T E S................:
  tditn LUN LU(SSID) Ch : Location :  #Success ByteXfered ART(uSec) MRT(uSec) :  #Success ByteXfered ART(uSec) MRT(uSec) :#Errs
------- --- -------- -- :--------- :---------- ---------- --------- --------- :---------- ---------- --------- --------- :-----
      4 253 00000004  2 :0x1000001 :  17247959 477464117248       235    664446 :    933375 48351206400      1735   1128777 :    0
      6 253 00000004  3 :0x1000001 :  17224923 476861496320       236    647369 :    924492 48300143104      1780   1226118 :    0
11.70.4+ SANtricity OS
      
-> tditlnall 3
Read/Write Completions
.........TDITLN.........:Initiator.:.................R E A D S................:...............W R I T E S................:
  tditn LUN LU(SSID) Ch : Location :  #Success ByteXfered ART(uSec) MRT(uSec) :  #Success ByteXfered ART(uSec) MRT(uSec) :#Errs
------- --- -------- -- :--------- :---------- ---------- --------- --------- :---------- ---------- --------- --------- :-----
      4 253 00000004  4 :0x1000001 :  17167803 463487405056      9150   2510841 :   1038936 58143469568       845   1078669 :    0
      6 253 00000004  5 :0x1000001 :  17149289 462841043456      9172   2553690 :   1026237 58029947392       886   1166025 :    0