E-Series IOM (ESM) temporary fails and returns to optimal in short time
Applies to
StorageGRID appliances SG5800, SG6160 (having E-Series E4000 storage controller)
Issue
- Following events are reported then resolved shortly
Controller shelf component failedTemperature sensor removedAn IOM (ESM) has reported an exception event
- STORAGE-ARRAY-PROFILE > SHELVES indicates:
-
IOM statustemporary changes toFailedthen shortly returns toOptimal - 2 IOMs, one with the storage controller serial number, and the other with the compute controller serial number
-
IOMs Detected: 2
IOM status: Optimal
Firmware Version: 0201
Configuration settings version: Not Applicable
Maximum data rate: 12 Gbps
Current data rate: 12 Gbps
Location: A
Card communication: OK
Trunking supported: No
Product ID: DE460C
Board ID: Not Available
Part number: 111-05275+A2
Serial number: <STORAGE CONTROLLER SERIAL NUMBER>
Date of manufacture: Not Available
IOM status: Optimal
Firmware Version: 0201
Configuration settings version: Not Applicable
Maximum data rate: 12 Gbps
Current data rate: 12 Gbps
Location: B
Card communication: OK
Trunking supported: No
Product ID: DE460C
Board ID: Not Available
Part number: 111-05277+A2
Serial number: <COMPUTE CONTROLLER SERIAL NUMBER>
Date of manufacture: Not Available
RECOVERY-GURU-PROCEDURES.HTMLindicatesNo data found