E-series reports Extended Fibre Channel link down
Applies to
- NetApp E-Series system
- Direct Attached
- StorageGRID Appliance
Issue
- Within E-Series support bundle or AutoSupport, the
major-event-log
reports FC port constantly flapping. Similarly, these events may be found in SANtricity System Manager under Support > Events.
Extended Fibre Channel link down (greater than one minute) - Host-side: controller in bay A, port 5
Fibre channel link down - Host-side: controller in bay A, port 5
Fibre channel link up - Host-side: controller in bay A, port 5
- Within E-Series support bundle or AutoSupport, the
fcDump
command output in thestate-capture-data
file may show a high amount of bad characters:
2806-A Our Num ::...Exchange Counts...:: Num ..Link Up..
Chip LinkStat Port Port :: :: Link Bad Bad
ID Logi ::Open Total Errors:: Down Char Frame
2-Src Up-Ptp e8 2 :: 0 236987 0:: 2 19 0
3-Src Up-Ptp e8 3 :: 0 4553 1:: 27 139145 0