Skip to main content
NetApp Knowledge Base

ASAr2 cluster join cannot be completed sucessfully

Views:
3
Visibility:
Public
Votes:
0
Category:
asa-r2
Specialty:
CORE
Last Updated:

Applies to

  • ASAr2
  • Cluster setup/join

Issue

The following error is seen on joining second node to existing asar2 cluster:

System start up .....Error: Insufficient candidate disks to be stamped. Required: 6 Actual:
cluster::> cluster show
node-01      true    true
node-02      true    true

Warning: Cluster operation (cluster add-node) for node "node-02" is
         not complete and the node is not fully functional. Run "cluster
         add-node" on that node to complete the operation.
2 entries were displayed.

If halted the following errors would be seen on the node failing to join the cluster:
May 26 11:50:01 [node-02:disk.encryptNoSupport:ALERT]: Detected FIPS-certified encrypting drive 0n.21, but FIPS drives are not supported on this node. 8 of 8 disks checked are FIPS-certified.
May 26 11:50:01 [node-02:diskown.errorDuringIO:error]: error 3 (disk failed) on disk 374E3630:59A00414:00253854:00000002:00000000:00000000:00000000:00000000:00000000:00000000 (S/N N/A) while opening disk
May 26 11:50:01 [node-02:diskown.errorDuringIO:error]: error 3 (disk failed) on disk 374E3630:59500103:00253843:00000011:00000000:00000000:00000000:00000000:00000000:00000000 (S/N N/A) while opening disk
May 26 11:50:01 [node-02:diskown.errorDuringIO:error]: error 3 (disk failed) on disk 374E3630:59A00526:00253854:00000002:00000000:00000000:00000000:00000000:00000000:00000000 (S/N N/A) while opening disk
May 26 11:50:01 [node-02:diskown.errorDuringIO:error]: error 3 (disk failed) on disk 374E3630:59A00489:00253854:00000002:00000000:00000000:00000000:00000000:00000000:00000000 (S/N N/A) while opening disk
May 26 11:50:01 [node-02:diskown.errorDuringIO:error]: error 3 (disk failed) on disk 374E3630:59500106:00253843:00000011:00000000:00000000:00000000:00000000:00000000:00000000 (S/N N/A) while opening disk
May 26 11:50:01 [node-02:diskown.errorDuringIO:error]: error 3 (disk failed) on disk 374E3630:59A00473:00253854:00000002:00000000:00000000:00000000:00000000:00000000:00000000 (S/N N/A) while opening disk
May 26 11:50:01 [node-02:diskown.errorDuringIO:error]: error 3 (disk failed) on disk 374E3630:59A00255:00253854:00000002:00000000:00000000:00000000:00000000:00000000:00000000 (S/N N/A) while opening disk
May 26 11:50:01 [node-02:diskown.errorDuringIO:error]: error 3 (disk failed) on disk 374E3630:59A00486:00253854:00000002:00000000:00000000:00000000:00000000:00000000:00000000 (S/N N/A) while opening disk

    

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.