Sg6060 Appliance reports Volume not on preferred path and ALB Host incompatible
Applies to
StorageGRID
- Sg6060
Issue
- ALB Incompatible Host Driver and VNOPP(Volume Not On Preferred Path) reported on SANtricity
- StorageGRID reports hardware alerts against the affected StorageGRID Appliance
Reported from E-Series logs, MEL event, as an example:
A:6/23/24, 1:27:54 AM (01:27:54) 22810 9103 Host multipath driver configuration error detected - Host StorageGRID Appliance <--CRITICAL
A:6/23/24, 1:26:52 AM (01:26:52) 22809 4011 Volume not on preferred path due to AVT/RDAC failover - Shelf 99, Bay A <--CRITICAL
A:6/23/24, 1:21:52 AM (01:21:52) 22808 2044 IO shipping implicit volume transfer - Volume StorageGRID-PGE-Backup
----> Shipped/Owned IOs: 62/0, Host ID: 6
A:6/23/24, 1:21:52 AM (01:21:52) 22807 212c Write-back caching fully restored - Shelf 99, Bay A
A:6/23/24, 1:21:52 AM (01:21:52) 22806 210a Controller cache not enabled or was internally disabled - Shelf 99, Bay A - Event: Give Volume Ownership-2
B:6/23/24, 1:21:53 AM (01:21:53) 22805 212c Write-back caching fully restored - Shelf 99, Bay B
B:6/23/24, 1:21:52 AM (01:21:52) 22804 210a Controller cache not enabled or was internally disabled - Shelf 99, Bay B - Event: Cache Reconfigure Sync-2
A:6/23/24, 12:26:06 AM (00:26:06) 22803 2049 Fail-back implicit volume transfer - Volume StorageGRID-PGE-Backup
A:6/23/24, 12:26:06 AM (00:26:06) 22802 212c Write-back caching fully restored - Shelf 99, Bay A
A:6/23/24, 12:26:06 AM (00:26:06) 22801 210a Controller cache not enabled or was internally disabled - Shelf 99, Bay A - Event: Take Volume Ownership-2
B:6/23/24, 12:26:07 AM (00:26:07) 22800 212c Write-back caching fully restored - Shelf 99, Bay B
B:6/23/24, 12:26:06 AM (00:26:06) 22799 210a Controller cache not enabled or was internally disabled - Shelf 99, Bay B - Event: Cache Reconfigure Sync-2
B:6/23/24, 12:21:36 AM (00:21:36) 22798 212c Write-back caching fully restored - Shelf 99, Bay B
B:6/23/24, 12:21:36 AM (00:21:36) 22797 210a Controller cache not enabled or was internally disabled - Shelf 99, Bay B - Event: Cache Reconfigure Sync-2
A:6/23/24, 12:21:36 AM (00:21:36) 22796 2044 IO shipping implicit volume transfer - Volume StorageGRID-PGE-Backup
----> Shipped/Owned IOs: 43/13, Host ID: 6
A:6/23/24, 12:21:36 AM (00:21:36) 22795 212c Write-back caching fully restored - Shelf 99, Bay A
A:6/23/24, 12:21:35 AM (00:21:35) 22794 210a Controller cache not enabled or was internally disabled - Shelf 99, Bay A - Event: Give Volume Ownership-2