Issue
- When creating a resource group of SCV, "SnapCenter Compatibility Error" occurs.
- The error doesn't occur after re-registering Storage Systems, but it occurs again after a while.
- When the error occurs,
SnapDriveSALDebug.log
reports an error like below.
Example:
2020-10-26T17:13:21.7485887+09:00 Critical SAL PID=[4500] TID=[4000] Error: The credentials for the storage system <IP ADDRESS> is not configured. Resolution: Please check if storage system <IP ADDRESS> is resolvable or add an entry to etc/hosts file.
- The IP address in the above message and another IP address of the same SVM are registered as Storage Systems.