Brocade switch security setting prevents OnCommand Insight(OCI) performance data collection
Applies to
OnCommand Insight7.3.x
Issue
- Attempting to poll for performance data for the Brocade switch datasource within OCI fails
- The customer has 2 switches in 1 Fabric where 1 switch is retrieving performance data, however, the other is not.
- Only a inventory works within OCI.
-
SNMPwalk returned with a error:
Host=SWITCH_BOT_1_11.eu.netapp.net:161
Timeout=1000ms Retries=1 Debug=false
Version=SNMPv2 Community=HAXX4A & sessionName=null_0
Variable = 0.0 Type = INT32
Value = NULL End of MIB Reached Total # of Requests = 1 Total # of Objects = 1