Automatic alerts not triggered for NVME flash cache failure
Applies to
- ONTAP 9.x
- ONTAP System Manager (OSM)
- ActiveIQ Unified Manager (AIQUM) 9.x
- ActiveIQ Digital Advisor (AIQDA)
- NVMe Flash Cache
Issue
- Automatic alerts not triggered for NVME flash cache failure while it shows
failedinsysconfig -a:
slot 3: Flash Cache NVMeSerial Number: Sxxxxxxxxxxxx0Part Number: 119-00329Hardware Revision: B0Firmware Version: NA01Firmware File: X3311_S000PM983NVMModel Name: X3311ACapacity: 1024 GBState: failed
- ONTAP raise the EMS event : nvme.card.degraded
[Node-01: kernel: nvme.card.degraded:error]: NVMe caching module in slot 3 with serial number Sxxxxxxxxxxxx0, and model number X3311A is degraded with status 0x400017.
- ONTAP/OSM/AIQUM didn't trigger any alert despite the NVME Flash cache is failed.
- AIQDA raise the event.