Applies to ONTAP Select VMWare ESXi vMotion Yes, the ISO can be safely detached while the Select system is up and running to allow you to move it to another host. An ISO image is showing attached to t...Applies to ONTAP Select VMWare ESXi vMotion Yes, the ISO can be safely detached while the Select system is up and running to allow you to move it to another host. An ISO image is showing attached to the ESXi host that ONTAP Select is running. For example- sdotconfig_mynode_ontap01-node.iso, and is further preventing a vMotion to another host. Verify settings on the host for adding or keeping CDs mounted after use. See the VMWare documentation Add or Modify a Virtual Machine CD or DVD Drive
Applies to ONTAP Select VMware Issue ONTAP Select node is Storage VMotioned while the node is booted Afterwards the node cannot be accessed by CLI, GUI and VMware console "Login incorrect. Access rest...Applies to ONTAP Select VMware Issue ONTAP Select node is Storage VMotioned while the node is booted Afterwards the node cannot be accessed by CLI, GUI and VMware console "Login incorrect. Access restricted to authorized users" error is given when attempting to log in CIFS and NFS access may also be affected
Applies to ONTAP Select ESXi Issue An ONTAP Select instance in an HA pair has unexpectedly gone into Takeover- An additional CLTFLT:HA Group Notification from SelectNode1-1 (CONTROLLER TAKEOVER COMPLE...Applies to ONTAP Select ESXi Issue An ONTAP Select instance in an HA pair has unexpectedly gone into Takeover- An additional CLTFLT:HA Group Notification from SelectNode1-1 (CONTROLLER TAKEOVER COMPLETE AUTOMATIC) ALERT has been reported for this system. In some cases, adapter error prevents command from being sent to device error messages might appear within EMS log
Applies to ONTAP Select (OTS) vCenter Issue ONTAP Select HA cluster crashes unexpectedly and upon reboot, the vCenter console shows the following errors: vm_fault: pager read error, pid 1 (init) [rety...Applies to ONTAP Select (OTS) vCenter Issue ONTAP Select HA cluster crashes unexpectedly and upon reboot, the vCenter console shows the following errors: vm_fault: pager read error, pid 1 (init) [rety 4] md0.uzip: UZIP(zlib) inflate() failed From vCenter console
Applies to ONTAP 9 VMware ESXi vCenter Issue Storage vMotion fails when migrating VMs from a NetApp backed NFS datastore to a VMware vSAN datastore within the same vCenter instance.
Applies to ONTAP 9 Issue Filer can see high Node utilization when _ocs_vserver workload is running. This workload can induce high CPU and Disk utilization causing CPU/Disk saturation. This can have a ...Applies to ONTAP 9 Issue Filer can see high Node utilization when _ocs_vserver workload is running. This workload can induce high CPU and Disk utilization causing CPU/Disk saturation. This can have a negative impact on other user workload as they would starve for resources. Alarm IO wait time is reported from the vCenter.
Applies to NetApp HCI NetApp ONTAP ESXi (All versions) vMotion Issue vMotion fails when trying to migrate virtual machines to and from certain ESXi hosts.
Applies to ONTAP Select ONTAP Deploy VMware ESXi VMware vCenter Issue Refresh cluster operation is not functioning with ONTAP Select Deploy appliance using either CLI or GUI
Applies to NetApp HCI VMware ESXi 6.5 VMware distributed switch (vDS) HA failover / Vmotion Issue After initiating vSphere HA failover, some of the virtual machines are powered on with virtual network...Applies to NetApp HCI VMware ESXi 6.5 VMware distributed switch (vDS) HA failover / Vmotion Issue After initiating vSphere HA failover, some of the virtual machines are powered on with virtual network interface card (vNIC) disconnected to vDS Reconnecting vNIC fails with error: Failed to connect virtual device ethernetX