- https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Sensor_7_or_sensor_13_over-temperature_warning_on_NS224Over-temperature on sensor 7 or 13, which is the CPU sensor on the NSM module A or B [node_name: dsa_worker4: ses.status.temperatureWarning:alert]: NS224NSM100 (S/N 123456789) shelf 0 on channel 0x te...Over-temperature on sensor 7 or 13, which is the CPU sensor on the NSM module A or B [node_name: dsa_worker4: ses.status.temperatureWarning:alert]: NS224NSM100 (S/N 123456789) shelf 0 on channel 0x temperature warning for Temperature sensor 7: non-critical status; overtemperature warning. [node_name: dsa_worker4: ses.status.temperatureWarning:alert]: NS224NSM100 (S/N 123456789) shelf 0 on channel 0x temperature warning for Temperature sensor 13: non-critical status; overtemperature warning.
- https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Sensor_for_NAND_Spare_Cap_4_through_7_is_failed_on_AFF_A700sApplies to AFF A700s NVRAM10P card Issue On the AFF A700s platform, the command output for system node environment sensors show , node run -node * -c environment status or AutoSupport section platform...Applies to AFF A700s NVRAM10P card Issue On the AFF A700s platform, the command output for system node environment sensors show , node run -node * -c environment status or AutoSupport section platform-sensors.xml might show a state of "failed" for NAND Spare Cap 4 through NAND Spare Cap 7. Example: AutoSupport content
- https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Temperature_Sensor_Warning_on_FAS2650_and_AFF_A200The shelf reports over-temperature on temprature sensor. Node1: dsa_worker3: ses.status.temperatureError:error]: DS224-12 (S/N SHFxxx) shelf 0 on channel 0b temperature error for Temperature sensor 11...The shelf reports over-temperature on temprature sensor. Node1: dsa_worker3: ses.status.temperatureError:error]: DS224-12 (S/N SHFxxx) shelf 0 on channel 0b temperature error for Temperature sensor 11: critical status; overtemperature failure. This module is on the rear of the shelf at the top left, on shelf module A. [ses.status.temperatureWarning:alert]: DS224-12 (S/N ***********) shelf 0 on channel 0b temperature warning for Temperature sensor 11: non-critical status.
- https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Node_sensors_output_not_working_and_failing_BMC_update_at_10_and_93_percentcomplete [from mgwd on node "<node_name>" (VSID: -1) to mgwd at took longer than 25 seconds to complete [from mgwd on node The BMC automatic or manual network-full firmware upgrade to 11.5 stops at 10...complete [from mgwd on node "<node_name>" (VSID: -1) to mgwd at took longer than 25 seconds to complete [from mgwd on node The BMC automatic or manual network-full firmware upgrade to 11.5 stops at 10%: Latest SP Firmware Update Start Timestamp: 7/10/2020 10:50:00 Latest SP Firmware Update Percentage Done: 10 Latest SP Firmware Update End Timestamp: 7/10/2020 10:50:40 Latest SP Firmware Update Start Timestamp: - Latest SP Firmware Update End Timestamp: -
- https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Two_Power_Supply_Units_PSUs_of_DS224c_have_no_sensor_reading_but_functional_normally[1] High critical: 52 C (125 F); high warning: 47 C (116 F) [2] High critical: 60 C (140 F); high warning: 55 C (131 F) [3] High critical: 60 C (140 F); high warning: 55 C (131 F) [4] High critical: 6...[1] High critical: 52 C (125 F); high warning: 47 C (116 F) [2] High critical: 60 C (140 F); high warning: 55 C (131 F) [3] High critical: 60 C (140 F); high warning: 55 C (131 F) [4] High critical: 60 C (140 F); high warning: 55 C (131 F) [5] High critical: 60 C (140 F); high warning: 55 C (131 F) [6] High critical: 62 C (143 F); high warning: 57 C (134 F) [7] High critical: 100 C (212 F); high warning: 90 C (194 F) Low critical: 0 C (32 F); low warning: 5 C (41 F)