    • https://kb.netapp.com/on-prem/solidfire/hardware_Kbs/How_to_clear_the_amber_blinking_lights_on_Element
      Applies to NetApp Element software NetApp SF-Series NetApp H-series Description Underlying (resolved) BMC alerts may still trigger warning LEDs on the system. As long as the System Event List (SEL) ha...Applies to NetApp Element software NetApp SF-Series NetApp H-series Description Underlying (resolved) BMC alerts may still trigger warning LEDs on the system. As long as the System Event List (SEL) has not been cleared, the warning LEDs will remain activated. This article will describe how to clear the SEL from BMC/IPMI. Note: Not all LED errors can be resolved by clearing the SEL. Refer Additional Information for further steps/investigation that may be required.
    • https://kb.netapp.com/Legacy/NetApp_HCI/OS/Correctable_ECC_memory_error_on_NetApp_HCI_compute_nodes
      Applies to NetApp HCI compute nodes Issue On booting: Memory Correctable ECC | Asserted Failing DIMM location(correctable memory component found) <DIMM location> On BMC logs: Memory Correctable ECC | ...Applies to NetApp HCI compute nodes Issue On booting: Memory Correctable ECC | Asserted Failing DIMM location(correctable memory component found) <DIMM location> On BMC logs: Memory Correctable ECC | Asserted
    • https://kb.netapp.com/on-prem/Switches/Broadcom-KBs/How_to_disable_BMC_access_on_a_Broadcom_BES-53248_switch
      Applies to Broadcom BES-53248 BMC Access Description This article describes the procedure to disable all external access to the BMC on Broadcom BES-53248 switches. Including: How to disable the BMC We...Applies to Broadcom BES-53248 BMC Access Description This article describes the procedure to disable all external access to the BMC on Broadcom BES-53248 switches. Including: How to disable the BMC Web GUI How to disable BMC IPMItool access How to disable BMC SSH access
    • https://kb.netapp.com/Legacy/NetApp_HCI/Hardware/Cant_login_to_BMC_interface
      Applies to NetApp H-series Baseboard Management Controller (BMC) Issue Can't log in to the BMC interface
    • https://kb.netapp.com/Legacy/NetApp_HCI/OS/ipmitool_is_not_installed_by_default_on_HCI_compute_nodes
      Applies to NetApp HCI compute nodes Issue ipmitool command is not installed by default on the ESXi image of NetApp HCI compute nodes
    • https://kb.netapp.com/Legacy/NetApp_HCI/Hardware/How_to_turn_on_the_UID_LED_light_on_an_H_series_2x4_chassis
      Applies to NetApp H410C H300E H500E H700E NetApp H410S H300S H500S H700S Answer Log into the BMC Web UI for the node: https://<bmc_ip> Go to Miscellaneous --> UID control Toggle UID ON / OFF. Example:...Applies to NetApp H410C H300E H500E H700E NetApp H410S H300S H500S H700S Answer Log into the BMC Web UI for the node: https://<bmc_ip> Go to Miscellaneous --> UID control Toggle UID ON / OFF. Example: Additional Information additionalInformation_text
    • https://kb.netapp.com/on-prem/solidfire/hardware_Kbs/SensorReadingFailed_IPMI_diagnostics_are_currently_unresponsive_on_Element_software
      NetApp SolidFire Active IQ reports alerts ‘sensorReadingFailed: IPMI diagnostics are currently unresponsive’ on NetApp Element software versions 12.3, 12.2, 11.x and higher and, 10.x or earlier. This ...NetApp SolidFire Active IQ reports alerts ‘sensorReadingFailed: IPMI diagnostics are currently unresponsive’ on NetApp Element software versions 12.3, 12.2, 11.x and higher and, 10.x or earlier. This could be caused by failure to obtain data.
    • https://kb.netapp.com/Legacy/NetApp_HCI/OS/How_to_reset_BMC_on_NetApp_HCI_compute_nodes
      Applies to NetApp H300E / H500E / H700E NetApp H410C Description This guide described the options to reset BMC on compute nodes This is helpful when the BMC is hung/not accessible
    • https://kb.netapp.com/Legacy/NetApp_HCI/OS/How_to_use_IPMICFG_on_NetApp_H410C_nodes
      Applies to NetApp H410C node Description How to install, use and remove IPMICFG tool
    • https://kb.netapp.com/Legacy/NetApp_HCI/OS/Set_IPMI_BMC_credentials_on_NetApp_HCI_compute_nodes
      Applies to NetApp HCI compute nodes Issue Credentials forgotten Cannot access with current credentials New credentials are needed
    • https://kb.netapp.com/on-prem/solidfire/Element_OS_Kbs/How_to_use_an_mNode_to_gather_BMC_logs_from_a_SolidFire_HCI_storage_or_compute_node
      Most commonly this procedure is performed on a cluster's management node (mNode) but this can also be done from any Element storage node or any other Linux host in the environment, provided that host ...Most commonly this procedure is performed on a cluster's management node (mNode) but this can also be done from any Element storage node or any other Linux host in the environment, provided that host has ipmitool installed. This method of gathering data is especially helpful when there is a suspected hardware issue and a node cannot boot into its operating system (whether Element or VMware) or when the operating system cannot be accessed for any other reason.