Skip to main content
NetApp Knowledge Base

Search

  • Filter results by:
    • View attachments
    Searching in
    About 4 results
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/EMULEX_Adapter_Showing_a_in_Switch_Port_Field_After_SFP_Replacement
      Post SFP replacement or hardware swap, the adapter is stuck in a hung state and does not allow connection despite being Online/UP. 1, N-port, <UP>) Board name: 111-03648 Serial Number: 1111111111 Firm...Post SFP replacement or hardware swap, the adapter is stuck in a hung state and does not allow connection despite being Online/UP. 1, N-port, <UP>) Board name: 111-03648 Serial Number: 1111111111 Firmware rev: 11.4.277.0 Host Port Id: 0x30b00 FC Node Name: 1:000:101010:111000 FC Port Name: 1:000:010101:000111 SFP Vendor: FINISAR CORP. SFP Part Number: FTLF8532P4BCV-N1 SFP Serial Number: P65ALNP SFP Capabilities: 8, 16 or 32 Gbit Link Data Rate: 32 Gbit Switch Port: ?
    • https://kb.netapp.com/on-prem/ontap/Ontap_OS/OS-KBs/ONTAP_SRAM_dump_fails_to_collect_when_hitting_parity_error_1_0x1201_error_2_0xe
      [Netapp1: fct_tpd_thread_3: fcp.io.status:debug]: STIO Adapter:1d, found hung cmd:0xfffff809b3a0a688(state=10, flags=0x2, ctio_sent=2/4,RecvExAddr=0x3ff, OX_ID=0xd6, RX_ID=0xffff,SID=0xd61c08, Cmd[28]...[Netapp1: fct_tpd_thread_3: fcp.io.status:debug]: STIO Adapter:1d, found hung cmd:0xfffff809b3a0a688(state=10, flags=0x2, ctio_sent=2/4,RecvExAddr=0x3ff, OX_ID=0xd6, RX_ID=0xffff,SID=0xd61c08, Cmd[28], req_q_free:0) [Netapp1: fct_tpd_thread_3: scsitarget.fcp.dump:debug]: FCP target SRAM dump generated for adapter 1d, fct_tpd_check_hung_commands: Command termination hung. [Netapp1: fct_tpd_thread_3: fcp.io.status:debug]: STIO Adapter 1d resetting with 31 ITNs and 16 commands to drain
    • https://kb.netapp.com/on-prem/ontap/da/SAN/SAN-KBs/ONTAP_initiator_port_shows_question_mark_for_the_switch_port_when_Emulex_XE201_adapter_is_used
      Impacted ONTAP versions 8.2.4P6, 9.0P1, 9.1, 9.1P10, 9.1P11, 9.1P3, 9.1P5, 9.1P6, 9.1P7, 9.1P8, 9.1P9, 9.2, 9.2P2, 9.3, 9.3P1, 9.3P2 In later versions of ONTAP this may be a cosmetic fabric discovery ...Impacted ONTAP versions 8.2.4P6, 9.0P1, 9.1, 9.1P10, 9.1P11, 9.1P3, 9.1P5, 9.1P6, 9.1P7, 9.1P8, 9.1P9, 9.2, 9.2P2, 9.3, 9.3P1, 9.3P2 In later versions of ONTAP this may be a cosmetic fabric discovery issue porterrshow output shows all ports to which affected initiator ports are connected, reporting huge number of "link fail" and "loss sig". fabriclog shows evidence of port flapping for same switch ports. Link break was detected on the impacted port
    • https://kb.netapp.com/on-prem/ontap/da/SAN/SAN-KBs/SRAM_DUMP_with_status_0x87800000_status1_0xa40c_status2_0x0_on_Emulex_HBA_with_ONTAP
      Applies to ONTAP 9.X Emulex HBA Issue SRAM DUMP is generated for the following status codes: Example: [NETAPP01: fct_tpd_thread_0: scsitarget.hwpfct.errorReset:notice]: An error was encountered in the...Applies to ONTAP 9.X Emulex HBA Issue SRAM DUMP is generated for the following status codes: Example: [NETAPP01: fct_tpd_thread_0: scsitarget.hwpfct.errorReset:notice]: An error was encountered in the FC target driver on Fibre Channel target adapter 4b. The adapter will be automatically reset to clear the status:0x87800000, status1:0xa40c, status2:0x0, DIP:1, RN:1, RDY:1, Dump owner:0 condition.