Skip to main content
NetApp Knowledge Base

Search

  • Filter results by:
    • View attachments
    Searching in
    About 49 results
    • https://kb.netapp.com/on-prem/Switches/Cisco-KBs/How_to_check_differences_between_running_and_startup_config_of_a_Cisco_cluster_switch
      Applies to Cisco cluster switch ONTAP 9 Description This article describes how to review and address unsaved configuration changed in a Cisco cluster switch.
    • https://kb.netapp.com/on-prem/Switches/Cisco-KBs/management_port_on_Cisco_Nexus__3132Q-V_not_accessible
      Applies to Cisco Nexus C3132Q-V Issue No access to a switch management interface (mgmt0) Cable checked.
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/How_to_configure_the_serviceport_on_a_CN1610_Cluster_Switch
      Applies to CN1610 Description This article provides minimal steps required in order to set up the Serviceport on the CN1610 as well as SSH in order to remotely access the switch.
    • https://kb.netapp.com/on-prem/ontap/mc/MC-KBs/Command_mapping_between_Cisco_and_NVIDIA_switches
      nv show --paginate on|off nv show --paginate on system nv show system nv show platform nv show platform environment nv show platform hardware show ip interface mgmt 0 nv show interface mgmt show runni...nv show --paginate on|off nv show --paginate on system nv show system nv show platform nv show platform environment nv show platform hardware show ip interface mgmt 0 nv show interface mgmt show running-config interface ethernet 1/9 nv show interface <if_name> nv show interface swp3 nv show interface neighbor nv show interface nv show interface --view=pluggables nv config show nv config show -o commands nv config show --startup -o commands nv config show --rev=startup
    • https://kb.netapp.com/on-prem/Switches/Broadcom-KBs/How_to_collect_data_from_a_BES-53248_switch
      Applies to Broadcom Ethernet Switch purchased from NetApp BES-53248 (X190005, X190005R) BES-53248-B (X190005-B, X190005R-B) Description This article describes how to collect data from a Broadcom BES-5...Applies to Broadcom Ethernet Switch purchased from NetApp BES-53248 (X190005, X190005R) BES-53248-B (X190005-B, X190005R-B) Description This article describes how to collect data from a Broadcom BES-53248 or BES-53248-B switch.
    • https://kb.netapp.com/on-prem/Switches/Cisco-KBs/Questions_for_qualified_Cisco_cluster_and_storage_network_switches
      It is the customer responsibility to register all the switches purchased from NetApp directly with Cisco or a Cisco reseller as well change entitlements or to renew their systems to get support for th...It is the customer responsibility to register all the switches purchased from NetApp directly with Cisco or a Cisco reseller as well change entitlements or to renew their systems to get support for the switches. If the switch was purchased with Cisco's onsite replacement entitlement, a Cisco onsite field engineer can reconfigure the switch for management access, load the desired NX-OS version, and reload the RCF file if instructed to do so prior to going onsite.
    • https://kb.netapp.com/on-prem/Switches/Cisco-KBs/How_to_collect_Cisco_show_tech-support_logs_via_ONTAP_9
      Applies to Cisco ONTAP 9 Description This article explains how to gather a show tech-support from a cluster switch in a system using ONTAP 9.5 and later. The data will be sent to NetApp via AutoSuppor...Applies to Cisco ONTAP 9 Description This article explains how to gather a show tech-support from a cluster switch in a system using ONTAP 9.5 and later. The data will be sent to NetApp via AutoSupport.
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Cisco_Nexus_cluster_switches_shows_both_PSUs_as_shutdown
      Applies to Cisco Nexus Cluster Switches PSU Model NXA-PAC-650W-PE or NXA-PAC-650W-PI Power supplies (including, but not limited to: NXA-PAC-650W-PE or NXA-PAC-650W-PI) could be seen reported as shutdo...Applies to Cisco Nexus Cluster Switches PSU Model NXA-PAC-650W-PE or NXA-PAC-650W-PI Power supplies (including, but not limited to: NXA-PAC-650W-PE or NXA-PAC-650W-PI) could be seen reported as shutdown on the switches as per "show environment power detail" command. sw2# show environment power detail Power Supply: Power Actual Actual Total Supply Model Output Input Capacity Status (Watts ) (Watts ) (Watts ) 1 NXA-PAC-650W-PE 0 W 0 W 0 W Shutdown 2 NXA-PAC-650W-PE 0 W 0 W 0 W Shutdown
    • https://kb.netapp.com/on-prem/ontap/Ontap_OS/OS-KBs/Unable_to_login_to_Cluster_Switch_after_SNMP_change
      Applies to How to monitor the CN1610 Cluster Interconnect Switch using the Cluster Switch Health Monitor used. Switch SNMP configuration: (Switch123) #show snmp Community-String Community-Access View ...Applies to How to monitor the CN1610 Cluster Interconnect Switch using the Cluster Switch Health Monitor used. Switch SNMP configuration: (Switch123) #show snmp Community-String Community-Access View Name IP Address snmp_netapp_comty1 Read Only Default All Community-String Group Name IP Address snmp_netapp_comty1 DefaultRead All Authentication trap is enabled. Target Address Type Community Version UDP Filter TO Retries Switch unreachable when the "Target Address" is being removed.
    • https://kb.netapp.com/on-prem/ontap/mc/MC-KBs/What_information_is_included_in_a_show_tech-support_on_a_BES-53248_switch
      #show version System Description............................. BES-53248A1, 3.4.4.4, Linux 4.4.117-ceeeb99d, 2016.05.00.05 Machine Type................................... BES-53248A1 Machine Model........#show version System Description............................. BES-53248A1, 3.4.4.4, Linux 4.4.117-ceeeb99d, 2016.05.00.05 Machine Type................................... BES-53248A1 Machine Model.................................. BES-53248 Serial Number.................................. <Switch Serial Number Here> Maintenance Level.............................. A Manufacturer................................... 0xbc00 Burned In MAC Address.......................... B4:A9:FC:98:1C:C1 Software Ver…
    • https://kb.netapp.com/on-prem/Switches/Broadcom-KBs/Remove_required_password_to_enter_privelege_exec_mode
      Applies to Brocade BES-53248 EFOS 3.4.4.5 Issue Removing the password to enter privilege exec mode (also called: enable mode or priv exec mode) on EFOS is not possible by setting a blank password