    • https://kb.netapp.com/Legacy/NetApp_HCI/Hardware/Troubleshoot_ESXi_unresponsive_state
      Applies to NetApp HCI Compute VMware vSphere ESXi 6.x Description This article provides documented steps to help determine why an ESXi host may be unresponsive
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Node_unable_to_boot_with_no_LEDs_or_SP_console_output_and_PSU_faults_reported_on_partner
      7/30/2021 10:35:08 node_name NOTICE monitor.chassisPowerSupply.degraded: Chassis power supply 2 is degraded: PSU2 Fan2 Fault is Unreadable 7/30/2021 10:35:07 node_name NOTICE monitor.chassisPowerSuppl...7/30/2021 10:35:08 node_name NOTICE monitor.chassisPowerSupply.degraded: Chassis power supply 2 is degraded: PSU2 Fan2 Fault is Unreadable 7/30/2021 10:35:07 node_name NOTICE monitor.chassisPowerSupply.degraded: Chassis power supply 2 is degraded: PSU2 Fan1 Fault is Unreadable 7/30/2021 10:34:20 node_name NOTICE monitor.chassisPowerSupply.degraded: Chassis power supply 1 is degraded: PSU1 Fan2 Fault is Unreadable
    • https://kb.netapp.com/on-prem/solidfire/Element_OS_Kbs/Troubleshooting_unresponsive_BMC_on_H610S
      Steps to troubleshoot unresponsive BMC on H610S, when BMC interface cannot be reached or BMC web page cannot be opened.
    • https://kb.netapp.com/Legacy/NetApp_HCI/OS/ESXi_host_unresponsive_due_to_NMLX_driver_fault
      Applies to NetApp H410C VMware ESXi NMLX_core driver NMLX Firmware Issue HCI compute node ESXi host becomes unresponsive and a forceful reboot is required
    • https://kb.netapp.com/hybrid/StorageGRID/Maintenance/StorageGRID_SG6000_Installation_failing_due_to_unresponsive_web_GUI
      Installation of a new SG6000 appliance is failing due to unresponsive Appliance Installer Page. WARNING -- Union <<class 'SYMbol.parser.RpcAcceptedReplyBody'>> at 0x7fad8778e2d0> discriminator value S...Installation of a new SG6000 appliance is failing due to unresponsive Appliance Installer Page. WARNING -- Union <<class 'SYMbol.parser.RpcAcceptedReplyBody'>> at 0x7fad8778e2d0> discriminator value SYSTEM_ERR does not have a corresponding qualifier WARNING -- Union <<class 'SYMbol.parser.RpcAcceptedReplyBody'>> at 0x7fad8774be50> discriminator value SYSTEM_ERR does not have a corresponding qualifier
    • https://kb.netapp.com/Legacy/AltaVault/NetApp_Cloud_Backup_formerly_AltaVault_becomes_unresponsive_under_high_backup_pressure
      Applies to NetApp Cloud Backup (formerly AltaVault) 4.4.1 AVA400 AVA800 Issue System becomes unresponsive no outgoing replication no backup possible