When there is one whole, unpartitioned SSD spare for Storage Pool assigned to only one node, you can receive this alert during takeover events as the takeover node replays the events for the node that...When there is one whole, unpartitioned SSD spare for Storage Pool assigned to only one node, you can receive this alert during takeover events as the takeover node replays the events for the node that is rebooting. However, if the Storage Pool provides allocation units only to hybrid aggregates that are owned by one of the nodes in the HA pair, then the SSD spare must be owned by that same node.
EMS message error "node_name-01: config_thread: callhome.spares.low:error]: Call home for SPARES_LOW: /aggr1_data/plex0/rg1" in one or more RAID groups and/or nodes when using ADP.
Applies to FAS2750 AFF A200 FAS8200 Internal shelf with ADPv1/v2 partitioned disks. External shelf with same internal disk models, but not partitioned. Issue AutoSupport message: Thu Apr 22 16:42:00 +...Applies to FAS2750 AFF A200 FAS8200 Internal shelf with ADPv1/v2 partitioned disks. External shelf with same internal disk models, but not partitioned. Issue AutoSupport message: Thu Apr 22 16:42:00 +0200 [node_name: config_thread: callhome.spares.low:error]: Call home for SPARES_LOW