    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/AFF_C190_AFF_A200_FAS2750_AFF_A800_attention_LED_ON_Set_by_Expander_BMC
      AFF C190 AFF A220 AFF A800 FAS2750 Controller attention LED on. BMC output of AFF A800 of command system fru led show all will report FRU LED ID 1 is on FRU LED ID 3 is on. FRU LED ID 4 is off BMC out...AFF C190 AFF A220 AFF A800 FAS2750 Controller attention LED on. BMC output of AFF A800 of command system fru led show all will report FRU LED ID 1 is on FRU LED ID 3 is on. FRU LED ID 4 is off BMC output of AFF C190, AFF A200, FAS2750 command system fru led show all will report BMC node_name> system fru led show all FRU LED ID 1 is off FRU LED ID 2 is on. Set by Expander/BMC FRU LED ID 3 is off FRU LED ID 4 is on FRU LED ID 5 is off FRU LED ID 6 is off FRU LED ID 7 is off FRU LED ID 8 is off
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Fault_LED_s_ON_with_no_actual_issues
      Attention LED is ON, even though there is no actual issue(s). In some scenarios the LED was ON due to a faulty component and remains ON after fixing it. ::> system health status show FRU LED status co...Attention LED is ON, even though there is no actual issue(s). In some scenarios the LED was ON due to a faulty component and remains ON after fixing it. ::> system health status show FRU LED status command indicates LED status is ON. Controller slot A: On (lit by Data ONTAP) DIMM slot 1: Off DIMM slot 2: Off DIMM slot 3: Off DIMM-NV slot 1: Off PCI slot 1: On PCI slot 2: Off ::*> system controller fru led show Node FRU Type Bay Slot State Lit By controller A 1 on SP
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Controller_attention_LED_remains_ON_even_after_rebooting_the_SP_module
      Record 1151: Wed Aug 14 05:57:59.774629 2024 [Agent.notice]: 837.448: 11 : Controller Attention LED asserted Record 1201: Thu Jan 01 00:01:00.329577 1970 [Agent.notice]: 307.464: 11 : Controller Atten...Record 1151: Wed Aug 14 05:57:59.774629 2024 [Agent.notice]: 837.448: 11 : Controller Attention LED asserted Record 1201: Thu Jan 01 00:01:00.329577 1970 [Agent.notice]: 307.464: 11 : Controller Attention LED asserted Record 1229: Thu Jan 01 00:01:00.889413 1970 [Agent.notice]: 662.334: 11 : Controller Attention LED asserted Record 1285: Thu Jan 01 00:01:00.782119 1970 [Agent.notice]: 427.277: 11 : Controller Attention LED asserted
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/FAS2554_attention_LED_ON
      FAS2554 Data ONTAP operating in 7-Mode Service Processor (SP) firmware 2.2.5P2 Controller attention LED ON ONTAP command storage show fault -v report status normal but all PSU with DC UNDER VOLTAGE no...FAS2554 Data ONTAP operating in 7-Mode Service Processor (SP) firmware 2.2.5P2 Controller attention LED ON ONTAP command storage show fault -v report status normal but all PSU with DC UNDER VOLTAGE node_name> storage show fault -v Enclosure Status: normal Element Status Status Bytes Status Descriptions 1: OK 01,00,04,A0 DC UNDER VOLTAGE, RQSTED ON 2: OK 01,00,04,A0 DC UNDER VOLTAGE, RQSTED ON 3: OK 01,00,04,A0 DC UNDER VOLTAGE, RQSTED ON 4: OK 01,00,04,A0 DC UNDER VOLTAGE, RQSTED ON
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Fault_LED_on_with_PCM_status_shows_as_SP_SHELF_FAULT_RQSTD
      Applies to FAS2720 ONTAP 9.9.1P15 Issue Controller fault LED on storage show fault -v outputs Node: node-01 Node: node-02 Enclosure Status: normal Channel: 0a Shelf: 0 Shelf Type: DS212-12 Product Ser...Applies to FAS2720 ONTAP 9.9.1P15 Issue Controller fault LED on storage show fault -v outputs Node: node-01 Node: node-02 Enclosure Status: normal Channel: 0a Shelf: 0 Shelf Type: DS212-12 Product Serial Number: SHFNC21xxxxxxxx Module Type: IOM12E Enclosure: 1: OK 01,00,02,00 FAIL Vendor Unique Element 88-IOM12E: (PCM) Element Status Status Bytes Status Descriptions 1: OK 01,01,00,00 2: OK 01,01,80,00 SP SHELF FAULT RQSTD There are no errors related to the shelf in the EMS log