Skip to main content
NetApp Knowledge Base

Search

  • Filter results by:
    • View attachments
    Searching in
    About 23 results
    • https://kb.netapp.com/on-prem/solidfire/hardware_Kbs/How_to_clear_the_amber_blinking_lights_on_Element
      Applies to NetApp Element software NetApp SF-Series NetApp H-series Description Underlying (resolved) BMC alerts may still trigger warning LEDs on the system. As long as the System Event List (SEL) ha...Applies to NetApp Element software NetApp SF-Series NetApp H-series Description Underlying (resolved) BMC alerts may still trigger warning LEDs on the system. As long as the System Event List (SEL) has not been cleared, the warning LEDs will remain activated. This article will describe how to clear the SEL from BMC/IPMI. Note: Not all LED errors can be resolved by clearing the SEL. Refer Additional Information for further steps/investigation that may be required.
    • https://kb.netapp.com/Legacy/NetApp_HCI/OS/Is_it_possible_to_delete_the_IPMI_user_Anonymous
      Applies to H410S, H410C, H300S, H500S, H700S, H300E, H500E, H700E Answer The anonymous user takes the first slot and can not be deleted or modified. Additional Information The anonymous account is dis...Applies to H410S, H410C, H300S, H500S, H700S, H300E, H500E, H700E Answer The anonymous user takes the first slot and can not be deleted or modified. Additional Information The anonymous account is disabled and will not accept any password. This is a safety feature , so that nobody can log in as anonymous. Refer Supermicro support faq 13632
    • https://kb.netapp.com/Legacy/NetApp_HCI/Hardware/IPMI_access_to_all_compute_nodes_is_failed
      IPMI access to all compute nodes is failed ipmitool command fails to contact IPMI. admin@SF-xxxx ~ $ sudo ipmitool -I lanplus -H BMC_IP -U ADMIN -P Password sel list Error: Unable to establish IPMI v2...IPMI access to all compute nodes is failed ipmitool command fails to contact IPMI. admin@SF-xxxx ~ $ sudo ipmitool -I lanplus -H BMC_IP -U ADMIN -P Password sel list Error: Unable to establish IPMI v2 / RMCP+ session Error: Unable to establish LAN session Error: Unable to establish IPMI v1.5 / RMCP session Power drain from the compute node can temporarily resolve this issue but the same issue returns after about 15~20 minutes
    • https://kb.netapp.com/Legacy/NetApp_HCI/Hardware/How_to_regenerate_self-signed_certificate_of_IPMI
      Applies to Intelligent Platform Management Interface (IPMI) Description Regenerating an expired self-signed certificate of Intelligent Platform Management Interface (IPMI)
    • https://kb.netapp.com/on-prem/solidfire/hardware_Kbs/SensorReadingFailed_IPMI_diagnostics_are_currently_unresponsive_on_Element_software
      NetApp SolidFire Active IQ reports alerts ‘sensorReadingFailed: IPMI diagnostics are currently unresponsive’ on NetApp Element software versions 12.3, 12.2, 11.x and higher and, 10.x or earlier. This ...NetApp SolidFire Active IQ reports alerts ‘sensorReadingFailed: IPMI diagnostics are currently unresponsive’ on NetApp Element software versions 12.3, 12.2, 11.x and higher and, 10.x or earlier. This could be caused by failure to obtain data.
    • https://kb.netapp.com/on-prem/solidfire/Element_OS_Kbs/HCC_upgrade_for_H410S_completes_without_upgrading_the_system
      MainProcess-Upgrade-10.221.5.16 | rtfi_node:35 | INFO | Initiating Node Upgrade of node=<NAME> nodeID=1 with URL=file:///sf/downloads/solidfire-rtfi:12.3.2.3/filesystem.squashfs", MainProcess-Upgrade-...MainProcess-Upgrade-10.221.5.16 | rtfi_node:35 | INFO | Initiating Node Upgrade of node=<NAME> nodeID=1 with URL=file:///sf/downloads/solidfire-rtfi:12.3.2.3/filesystem.squashfs", MainProcess-Upgrade-10.221.5.16 | rtfi_monitor:183 | INFO | Node upgrade status: URTFIStopServices 0%: Stopping all systemd services and sockets", MainProcess-Upgrade-10.221.5.16 | rtfi_monitor:183 | INFO | Node upgrade status: FinishFailure 0%: RTFI Rollback complete",
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/System_shutdown_due_to_SP_heartbeat_stopped_on_AFF_A250_or_FAS500f
      SP heartbeat stopped on AFF A250 or FAS500f causing system shutdown. Article provides steps to resolve the issue and recover the BMC.
    • https://kb.netapp.com/Legacy/NetApp_HCI/Hardware/Node_offline_with_Management_controller_unavailable_errors_in_SEL
      Applies to NetApp H610S storage node System Event Log (SEL) Issue Node goes offline with Management controller unavailable errors found in System Event Log (SEL): SEL Record ID : 004b Record Type : 02...Applies to NetApp H610S storage node System Event Log (SEL) Issue Node goes offline with Management controller unavailable errors found in System Event Log (SEL): SEL Record ID : 004b Record Type : 02 Timestamp : 08/26/2020 18:45:09 Generator ID : 0020 EvM Revision : 04 Sensor Type : Management Subsystem Health Sensor Number : 8f Event Type : Sensor-specific Discrete Event Direction : Deassertion Event Event Data : 03ffff Description : Management controller unavailable
    • https://kb.netapp.com/Legacy/NetApp_HCI/Hardware/NetApp_H410C_compute_node_has_CATERR_alert_and_not_responding
      Applies to NetApp H410C Issue H410C compute node is not responding at vCenter IPMI/BMC is accessible but remote console is not responding to keyboard System Event Log (SEL) of the node at the IPMI/BMC...Applies to NetApp H410C Issue H410C compute node is not responding at vCenter IPMI/BMC is accessible but remote console is not responding to keyboard System Event Log (SEL) of the node at the IPMI/BMC shows CATERR has occured - Assertion at the Processor sensor
    • https://kb.netapp.com/Legacy/NetApp_HCI/Hardware/Cant_login_to_BMC_interface
      Applies to NetApp H-series Baseboard Management Controller (BMC) Issue Can't log in to the BMC interface
    • https://kb.netapp.com/on-prem/solidfire/Element_OS_Kbs/IPMI_remote_console_window_is_blank_and_not_responding
      Applies to Intelligent Platform Management [Interface] (IPMI) Issue When opening the remote IPMI console window, the console window is blank and cannot display the screen