Skip to main content
NetApp Knowledge Base

Search

  • Filter results by:
    • View attachments
    Searching in
    About 18 results
    • https://kb.netapp.com/on-prem/E-Series/SANtricity-OS-KBs/How_to_Decode_Mode_select_for_redundant_controller_page_2C_received
      Applies to E-Series Description Mode select for redundant controller page 2C received
    • https://kb.netapp.com/data-mgmt/OTV/SRA_Kbs/Incorrect_status_Failover_in_Progress_is_reported_for_SRA_in_SRM
      Incorrect status 'Failover in Progress' is reported for SRA in SRM after reprotect operation
    • https://kb.netapp.com/on-prem/ontap/Ontap_OS/OS-KBs/Storage_takeover_or_giveback_failed__operation_was_vetoed_by_dump_operations
      During Giveback, ONTAP reports a  pause on error due to SFO giveback veto; when takeover is failed, storage failover show-takeover output.
    • https://kb.netapp.com/on-prem/ontap/da/SAN/SAN-KBs/Oracle_database_failed_over_during_giveback
      Applies to Data ONTAP 8.2 7-Mode Fibre Channel (FC) LUNs Oracle hosts Issue After performing giveback of a taken over NetApp node, Oracle database failed over
    • https://kb.netapp.com/on-prem/ontap/Ontap_OS/OS-KBs/Outage_due_to_no_failover_targets_during_node_removal
      Applies to ONTAP 9 Node Removal Issue While attempting to remove nodes from the cluster, LIF failover was unsuccessful following reboots. Sun May 05 17:20:25 -0400 [cluster1: vifmgr: vifmgr.lifdown.no...Applies to ONTAP 9 Node Removal Issue While attempting to remove nodes from the cluster, LIF failover was unsuccessful following reboots. Sun May 05 17:20:25 -0400 [cluster1: vifmgr: vifmgr.lifdown.noports:alert]: LIF data_LIF (on virtual server 2), IP address 1.1.1.1, currently cannot be hosted on node cluster1-01, port e0c, or any of its failover targets, and is being marked as down.
    • https://kb.netapp.com/on-prem/ontap/DP/SnapMirror/SnapMirror-KBs/SVMDR_or_SnapMirror_update_resync_fails_with_One_or_more_Snapshot_copies_snapshot_is_owned_by_other_relationship
      Applies to ONTAP 9 SnapMirror SVMDR Revese Resync Issue After a flip-resync (reverse resync) of a SVMDR or SnapMirror relationship, snapmirror update or resync fails with: Transfer for volume "[%VOLUM...Applies to ONTAP 9 SnapMirror SVMDR Revese Resync Issue After a flip-resync (reverse resync) of a SVMDR or SnapMirror relationship, snapmirror update or resync fails with: Transfer for volume "[%VOLUME%]" failed. Reason: One or more Snapshot copies on volume [%VOLUME%] are owned by other relationships or operations and will not be present on the source after this operation. Accordingly, those relationships or operations might be affected.
    • https://kb.netapp.com/on-prem/ontap/da/NAS/NAS-KBs/How_To_analyze_and_troubleshoot_LIF_connectivity_issues_in_a_non_routed_network
      Applies to ONTAP 9 LIF on non-routed network (subnet) Description After ONTAP upgrade (including failover) a LIF cannot be reached by (some) clients, anymore Takeover and Giveback of the cluster nodes...Applies to ONTAP 9 LIF on non-routed network (subnet) Description After ONTAP upgrade (including failover) a LIF cannot be reached by (some) clients, anymore Takeover and Giveback of the cluster nodes, restored the access for the clients Root Cause Analysis did not reveal any issue on the ONTAP side (it was found that other clients on the same lif/network were able to connect)
    • https://kb.netapp.com/Cloud/BlueXP/Cloud_Manager/Unable_to_find_Advanced_Allocation_tab_under_Advanced_option_in_Cloud_Manager
      Applies to Cloud Manager Cloud Volumes ONTAP Issue Unable to create/delete the aggregate from Cloud Manager.
    • https://kb.netapp.com/on-prem/ontap/da/NAS/NAS-KBs/Vserver_Lif_unreachable_after_Failover_due_to_incorrect_IPspace_configuration
      Applies to ONTAP 9 IPspace Failover Issue When a node goes down and/or a Lif fails over to another node, the Vserver/Lif is not reachable anymore Vserver is not configured in any IPspace, so will be i...Applies to ONTAP 9 IPspace Failover Issue When a node goes down and/or a Lif fails over to another node, the Vserver/Lif is not reachable anymore Vserver is not configured in any IPspace, so will be in Default IPspace Default IPspace does not have any (functionally identical) network ports, to which the Lif can failover to
    • https://kb.netapp.com/on-prem/ontap/Ontap_OS/OS-KBs/LIFs_go_down_during_a_Failover
      Applies to ONTAP 9.x Logical Interface (LIF) Flash Cache Issue Vifmgr is going "Out-Of-Quorum" during a Failover, which results in LIFs being down. [kern_vifmgr:info:5605] Notice: online_status_callba...Applies to ONTAP 9.x Logical Interface (LIF) Flash Cache Issue Vifmgr is going "Out-Of-Quorum" during a Failover, which results in LIFs being down. [kern_vifmgr:info:5605] Notice: online_status_callback: RDB unit is offline
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/iSCSI_LUN_failover_fails_during_node_port_failure
      Applies to Data ONTAP 7 mode Issue LUN failover was not initiated automatically after home node/port is offline.