    • https://kb.netapp.com/on-prem/ontap/mc/MC-KBs/FC-SAS_bridge_reports_an_error
      Misconfiguration of the bridge can cause outages and severe issues. The following command is run to identify the error message: ATTO_10.64.25.161 ok 8/31/2016 15:12:42 +00:00 - ATTO_10.64.25.165 ok 8/...Misconfiguration of the bridge can cause outages and severe issues. The following command is run to identify the error message: ATTO_10.64.25.161 ok 8/31/2016 15:12:42 +00:00 - ATTO_10.64.25.165 ok 8/31/2016 15:12:42 +00:00 - ATTO_10.64.25.166 ok 8/31/2016 15:12:42 +00:00 - ATTO_10.64.25.169 ok 8/31/2016 15:12:42 +00:00 - ATTO_10.64.25.170 error 8/30/2016 14:04:12 +00:00 "ATTO_10.64.25.170(20000010866286e2):Bridge is Unreachable over Management Network."
    • https://kb.netapp.com/on-prem/ontap/Perf/Perf-KBs/What_is_PEAK_PERFORMANCE_line_in_Active_IQ
      The delta between the current and optimal values is the Headroom Available for the resource. If the current values (or current_utilization in AIQUM) exceed the optimal point values (or peak_performanc...The delta between the current and optimal values is the Headroom Available for the resource. If the current values (or current_utilization in AIQUM) exceed the optimal point values (or peak_performance in AIQUM) it is expected to see potentially high increases in resource latency which could translate to increases in protocol/client data latency. The optimal point of ops derived from the latency/utilzation curve for the given interval (daily, hourly, etc).
    • https://kb.netapp.com/on-prem/solidfire/Element_OS_Kbs/Can__NetApp_Active_IQ_Unified_Manager_manage_monitor_SolidFire_HCI_clusters
      Applies to NetApp Element Software Answer No, only NetApp SolidFire Active IQ can be used with SolidFire/HCI clusters Additional Information
    • https://kb.netapp.com/Legacy/ONTAP/Clustered_Data_ONTAP_8/How_to_configure_DNS_per_SVM_for_versions_later_than_clustered_Data_ONTAP_8.2.1
      Applies to Clustered Data ONTAP 8.2 Description This document explains how to configure DNS per SVM for versions later than clustered Data ONTAP 8.2.1.
    • https://kb.netapp.com/on-prem/ontap/da/NAS/NAS-KBs/User_sends_reset_packet_after_Negotiate_Protocol_Request_from_the_storage_system
      Fri Nov 24 12:56:16 GMT [filer1:cifs.server.errorMsg:error]: CIFS: Error for server \\DC1: Error while negotiating protocol with server STATUS_IO_TIMEOUT. Fri Nov 24 12:56:46 GMT [filer1:cifs.server.e...Fri Nov 24 12:56:16 GMT [filer1:cifs.server.errorMsg:error]: CIFS: Error for server \\DC1: Error while negotiating protocol with server STATUS_IO_TIMEOUT. Fri Nov 24 12:56:46 GMT [filer1:cifs.server.errorMsg:error]: CIFS: Error for server \\DC2: Error while negotiating protocol with server STATUS_IO_TIMEOUT. Fri Nov 24 12:57:16 GMT [filer1:cifs.server.errorMsg:error]: CIFS: Error for server \\DC3: Error while negotiating protocol with server STATUS_IO_TIMEOUT.
    • https://kb.netapp.com/on-prem/solidfire/hardware_Kbs/AutoSupport_Message__System_memory_is_low_on_Element_9_x
      Applies to NetApp storage clusters running Element Software Element Software versions 9.3 through 10.1 Issue Alert shows in NetApp SolidFire Active IQ: System memory is low. Adding additional nodes or...Applies to NetApp storage clusters running Element Software Element Software versions 9.3 through 10.1 Issue Alert shows in NetApp SolidFire Active IQ: System memory is low. Adding additional nodes or manually purging deleted volumes may help reduce memory usage.
    • https://kb.netapp.com/hybrid/StorageGRID/Grid_Tenant_Manager/StorageGRID_-_Gateway_Nodes_not_showing_up_in_Active_IQ
      Applies to StorageGRID Gateway Node Answer No not at this point ,only nodes having a storage controller will be visible in AIQ Additional Information
    • https://kb.netapp.com/on-prem/solidfire/Element_OS_Kbs/What_does_the_alert_Usable_Space_Less_Than_60_mean
      This alert defines on Active IQ as following policy: WARNING Usable Space Less Than 60% ERROR Usable Space Less Than 40% CRITICAL Usable Space Less Than 20% The alert reports on Active IQ if the usabl...This alert defines on Active IQ as following policy: WARNING Usable Space Less Than 60% ERROR Usable Space Less Than 40% CRITICAL Usable Space Less Than 20% The alert reports on Active IQ if the usable space of cluster block capacity less than above threshold. Alert Policy: Usable Space Less Than 60% Historical Detail: This alert has occurred 1 times in the last 30 days. This alert indicates the current usage of block capacity and has no impact on the cluster.
    • https://kb.netapp.com/data-mgmt/Digital-Advisor-KBs/Unable_to_see_any_visualization_options_in_Active_IQ
      Applies to ONTAP 9.7P3 4 Node Fabric Metrocluster Issue In the ActiveIQ GUI the visualization tabs (such as cable diagram) for a system aren't viewable Receive the following type of message when tryin...Applies to ONTAP 9.7P3 4 Node Fabric Metrocluster Issue In the ActiveIQ GUI the visualization tabs (such as cable diagram) for a system aren't viewable Receive the following type of message when trying to view them Cabling Diagram is not supported for this MCC configuration
    • https://kb.netapp.com/on-prem/ontap/Perf/Perf-KBs/High_disk_latency_after_upgrade_due_to_Flash_Cache_options_being_disabled
      Applies to ONTAP 9.3 and later External cache options Issue High latency is seen after an ONTAP upgrade from 9.3 to higher releases Note: This can be seen due to an Active IQ alert and not due to late...Applies to ONTAP 9.3 and later External cache options Issue High latency is seen after an ONTAP upgrade from 9.3 to higher releases Note: This can be seen due to an Active IQ alert and not due to latency Disk utilization is at 100% but before was lower before upgrade Flash Cache options are off Cluster1::> system node external-cache show Node enabled rewarm mbuf-inserts pcs-size hya-caching ---------- ------- ------ ------------ -------- ----------- node1 true false false 256 false
    • https://kb.netapp.com/on-prem/solidfire/Element_OS_Kbs/AutoSupport_Message__Block_Service_Fullness_Disparity
      The KB article shows what causes the AutoSupport Message: Block Service Fullness Disparity > 10% or Detected block service fullness disparity of over 10%, and the Solution for when these messages are ...The KB article shows what causes the AutoSupport Message: Block Service Fullness Disparity > 10% or Detected block service fullness disparity of over 10%, and the Solution for when these messages are seen.