Top SLES Issues/Workarounds/Best Practices for NFS v3/v4.0
Applies to
- NetApp FAS controllers
- Data ONTAP 7-Mode
- Clustered Data ONTAP
Answer
This article provides information on the top known issues, workarounds, and best practices for SLES clients, when used with NetApp FAS controllers running Data ONTAP 7-Mode or clustered Data ONTAP.
Issue 1
SLES 11 SP1/SP2/SP3: NFS v3/4.0: The application reports EIO during storage failovers.
Description: On storage failovers, NFS v3/v4.0 applications running over
tcp
might encounter a failure reporting the following errors:
' error no. 5 (EIO) '
' error no. 13 (Permission denied) '
' error no. 2 (No such file or directory) '
Issue 2
SLES11 SP1 /SP2: NFS v4.0: Improper file ownership for the NFS v4 mounts, which results in unavailability of files under automount mounts.
Workaround
- Make sure the domain in
/etc/idmapd.conf
file matches the domain setting for NFS option "-v4-id-domain" on the NFS server, and restart/etc/init.d/nfs
on the client to map the correct users while mounting with NFS v4.0. - The BUG link for the reference from Novell can be found here.
Best Practices:
See TR-4067 for Clustered Data ONTAP NFS Best Practice and Implementation Guide.
Additional Information
additionalInformation_text