Skip to main content
NetApp Knowledge Base

H610S node offline Volt_CPU1_ABC VoltageĀ  Lower Critical

Views:
168
Visibility:
Public
Votes:
0
Category:
h-series
Specialty:
hci
Last Updated:

Applies to

  • NetApp H610S
  • NetApp Element software 12.3.0.958 or below

Issue

  • Node offline and ping is not available, BMC WebUI is also not reachable. (also may happen during the upgrade from 12.3.0 to 12.7)
  • After the power drain the node still can't boot with a black TUI screen, from the BMC WebUI the log is below:

[Crtical] [NM Status] [Management Subsystem Health] Controller access degraded or unavailable Self-Test Result:0x57 0x02 - Asserted
[Critical]  [Volt_CPU1_ABC] [Voltage]  Lower Critical - Going Low (Reading: 0.028 Volts/ Threshold: 1.078 Volts) - Asserted
[Critical]  [SPS FW Health] [OEM]  Firmware Status - Image Execution Failed - Asserte
[Warning]  [SPS FW Health] [OEM]  Firmware Status - UMA Operation Error - Asserted
[Critical]  [CATERR]  [Processor] IERR - Asserted
[Critical]  [CATERR]  [Processor] IERR - Asserted

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.