How to confirm that an AltaVault drive requires replacement
Applies to
- AltaVault
- AVA-400
- AVA-800
Description
- AltaVault drives may report as 'failed' with the following error message when actually being in a 'rebuild' state
AVADSF:AltaVault Notification from [node name] (Disk Failed: Shelf S/N [serial number], Slot [number], Model [AVA model], Disk S/N [serial number]) ALERT
- Or the following alert could be received
An error has been detected with one or more disks. Shelf [serial number] Disk Slot [number] (model: [Drive model and firmware], serial number: [Drive s/n]): undefined
- This occurs when the system is performing a diagnostic test against the drive.
- If the drive passes, it will report as '
rebuild
' and will be added back to the RAID group upon completion.- Upon successful completion, the drive will show as '
online
'.
- Upon successful completion, the drive will show as '
- If the drive fails, it will report as '
failed
'.