NS224 Shelf fault led on with voltage sensor status N/A after upgrade shelf firmware to FW 0162

Views:
153
Visibility:
Public
Votes:
0
Category:
disk-shelves
Specialty:
hw
Last Updated:

Applies to

  • AFF A400
  • NS224 NVMe Drive Shelf

Issue

  • After upgrade shelf FW to 0162, shelf fault led on, with multiple voltage sensors reading as N/A, but both PSUs are normal:

Channel: 0x
Shelf: 0
SES device path: local access: 0x.0.1.99
Module type: NSM100; monitoring is active
Shelf status: critical condition
SES Configuration, shelf 0:
 logical identifier=0x00a0980000525c26
 vendor identification=NETAPP
 product identification=NS224NSM100
 product revision level=0162
Vendor-specific information:
 Product Serial Number: SHFNCxxxxxxxxxx
Status reads attempted: 46902; failed: 1
Voltage Sensor installed element list: 1, 2, 3, 4; with error: 2, 4
Shelf voltages by element:
  [1] 12.02 Volts  Normal voltage range
  [2] <N/A> sensor condition <N/A>
  [3] 12.01 Volts  Normal voltage range
  [4] <N/A> sensor condition <N/A>

  • STORAGE-FAULT shows:


Enclosure Status: critical
Channel: 0x
Shelf: 0
Shelf Type: NS224NSM100
Module Type: NSM100

Enclosure:
Element Status         Status Bytes  Status Descriptions
  1: OK                01,00,02,00   FAIL

Voltage Sensors:
Element Status         Status Bytes  Status Descriptions
  1: OK                01,00,04,C6
  2: CRITICAL          02,01,00,00   CRIT UNDER
  3: OK                01,00,04,C2
  4: CRITICAL          02,01,00,00   CRIT UNDER

  • EMS shows sensor 2 and sensor 4 are on the unknown location:

7/21/2022 09:52:51  Nodename-02      EMERGENCY     ses.status.volError: NS224NSM100 (S/N SHFNCxxxxxxxxxxx) shelf 0 on channel 0x voltage error for Voltage sensor 4: critical status; voltage low critical. This element is on the unknown location.
7/21/2022 09:52:51  Nodename-02      EMERGENCY     ses.status.volError: NS224NSM100 (S/N SHFNCxxxxxxxxxxx) shelf 0 on channel 0x voltage error for Voltage sensor 2: critical status; voltage low critical. This element is on the unknown location.
7/21/2022 06:49:34  Nodename-02      ALERT         monitor.shelf.fault: Critical fault reported on disk storage shelf attached to channel 0x. Check fans, power supplies, disks, and temperature sensors.

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.