Skip to main content
NetApp Knowledge Base

Brocade 8510 or DCX Fiber Channel Switch may experience over heating

Views:
877
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
brocade
Last Updated:

Applies to

  • Brocade DCX8510
  • Brocade DCX switch

Issue

 

  • Brocade DCX or 8510 reporting high blade temperatures, and that some blades were marked `faulty` due to over temperature conditions.
  • Investigation further indicated that the ambient temperature in the data center, and as measured at the DCX fan intakes were within normal limits.
  • Replacement of the faulted blade does not resolve the issue
  • Overtemp condition is limited to a few of the sensors but most are in acceptable ranges
  • RASLOG will display warning and critical error messages:
2016/02/13-18:17:20:637749, [HIL-1501], 46454/3937, SLOT 7 | CHASSIS, WARNING, DCXa, Slot 5, high temperature (69).
2016/02/13-18:21:38:105359, [HIL-1502], 46461/3944, SLOT 7 | FFDC | CHASSIS, CRITICAL, DCXa, Slot 5, high temperature (74). Unit will be shut down in 2 minutes if temperature remains high.
2016/02/13-18:23:42:477105, [HIL-1503], 46469/3948, SLOT 7 | FFDC | CHASSIS, CRITICAL, DCXa, Slot 5, unit shutting down.
  • Output of the tempshow command will flag any components operating above the maximum temperature:
DCXa:FID128:root> tempshow
Sensor  Slot    State             Centigrade     Fahrenheit
ID
========================================================
32    5     Above maximum          72            161
sensor 32: (Temperature) is Above maximum, value is 72 C
  • If the blade is shutdown due to the high termperature, it will show up as "FAULTY (5)" in the slotshow command output:


slotshow -m
Slot   Blade Type     ID    Model Name     Status
--------------------------------------------------
5     CORE BLADE   98     CR16-8         FAULTY (5)

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.