Skip to main content
NetApp Knowledge Base

show install all impact kickstart command on Cisco 5596 switch fails

Views:
293
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
hw
Last Updated:

Applies to

Cisco cluster switch 5596

Issue

Verifying the image downloaded to the switch fails

show install all impact kickstart n5000-uk9-kickstart.7.3.7.N1.1b.bin system n5000-uk9.7.3.7.N1.1b.bin


Verifying image bootflash:/n5000-uk9-kickstart.7.3.7.N1.1b.bin for boot variable "kickstart".
[#                   ]   0%[####################] 100% -- SUCCESS

Verifying image bootflash:/n5000-uk9.7.3.7.N1.1b.bin for boot variable "system".
[#                   ]   0%[#                   ]   0% -- FAIL. Return code 0x4045001F (image MD5 checksum error).

Install has failed. Image verification failed (0x40930011)


================================================================================
Error Id: 0x4045001F
Error Facility: bootvar
Error Description: image MD5 checksum error

Image MD5 checksum error can happen due to one of the following reason(s):
[1] The target image is possibly corrupt. Copy the target image again and try the "install all" command

================================================================================

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.