Brocade switch shows the WARNING: Frame timeout detected, tx port xx rx port yy
Applies to
Brocade switch
Issue
- Brocade switch shows the WARNING "
Frame timeout detected
".
Example:
2020/11/02-11:54:40, [AN-1014], 95864, FID 128, INFO, switch01, Frame timeout detected, tx port 2 rx port 21, sid 31301, did 50200, timestamp 2020-11-02 11:54:40 .
- "
porterrshow
" shows a large number of bad statistics on the affected port.
Example:
frames enc crc crc too too bad enc disc link loss loss frjt fbsy c3timeout pcs uncor
tx rx in err g_eof shrt long eof out c3 fail sync sig tx rx err err
0: 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
1: 975.2m 1.0g 0 0 0 0 0 0 0 146 0 0 0 0 0 0 71 0 0
2: 12.4m 6.2m 0 1.0m 988.3k 0 47 19.9k 0 237.6k 3 0 1 0 0 236.2k 50 280.2m 0
3: 432.4m 872.3m 0 0 0 0 0 0 0 35 0 0 0 0 0 0 6 0 0
4: 611.0m 437.6m 0 0 0 0 0 0 0 58 0 0 0 0 0 0 25 0 0
- "
sfpshow
" shows RX/TX power of the affected port is lower than 300uW.
Example:
=============
Port 2:
=============
Identifier: 3 SFP
Connector: 7 LC
Transceiver: 7004404000000000 4,8,16_Gbps M5 sw Short_dist
Encoding: 6 64B66B
Baud Rate: 140 (units 100 megabaud)
Length 9u: 0 (units km)
Length 9u: 0 (units 100 meters)
Length 50u (OM2): 3 (units 10 meters)
Length 50u (OM3): 10 (units 10 meters)
Length 62.5u:0 (units 10 meters)
Length Cu: 0 (units 1 meter)
Vendor Name: BROCADE
Vendor OUI: 00:05:1e
Vendor PN: 57-0000088-01
Vendor Rev: A
Wavelength: 850 (units nm)
Options: 003a Loss_of_Sig,Tx_Fault,Tx_Disable
BR Max: 0
BR Min: 0
Serial No: HAF6184100018PB
Date Code: 181010
DD Type: 0x68
Enh Options: 0xfa
Status/Ctrl: 0x0
Pwr On Time: 1.64 years (14349 hours)
E-Wrap Control: 0
O-Wrap Control: 0
Alarm flags[0,1] = 0x5, 0x0
Warn Flags[0,1] = 0x5, 0x0
Temperature: 51 Centigrade
Current: 7.508 mAmps
Voltage: 3272.9 mVolts
RX Power: -8.1 dBm (155.8uW)
TX Power: -3.0 dBm (500.6 uW)