Brocade switch

Issue

  • Brocade switch shows the WARNING "Frame timeout detected".

Example:

2020/11/02-11:54:40, [AN-1014], 95864, FID 128, INFO, switch01, Frame timeout detected, tx port 2 rx port 21, sid 31301, did 50200, timestamp 2020-11-02 11:54:40 .

  • "porterrshow" shows a large number of bad statistics on the affected port.

Example:

          frames      enc    crc    crc    too    too    bad    enc   disc   link   loss   loss   frjt   fbsy  c3timeout    pcs    uncor
       tx     rx      in    err    g_eof  shrt   long   eof     out   c3    fail    sync   sig                  tx    rx     err    err
  0:    0      0      0      0      0      0      0      0      0      0      0      0      0      0      0      0      0      0      0   
  1:  975.2m   1.0g   0      0      0      0      0      0      0    146      0      0      0      0      0      0     71      0      0   
  2:   12.4m   6.2m   0      1.0m 988.3k   0     47     19.9k   0    237.6k   3      0      1      0      0    236.2k  50    280.2m   0   
  3:  432.4m 872.3m   0      0      0      0      0      0      0     35      0      0      0      0      0      0      6      0      0   
  4:  611.0m 437.6m   0      0      0      0      0      0      0     58      0      0      0      0      0      0     25      0      0  

  • "sfpshow" shows RX/TX power of the affected port is lower than 300uW.

Example:

=============
Port  2:
=============
Identifier:  3    SFP
Connector:   7    LC
Transceiver: 7004404000000000 4,8,16_Gbps M5 sw Short_dist
Encoding:    6    64B66B
Baud Rate:   140  (units 100 megabaud)
Length 9u:   0    (units km)
Length 9u:   0    (units 100 meters)
Length 50u (OM2):  3    (units 10 meters)
Length 50u (OM3):  10   (units 10 meters)
Length 62.5u:0    (units 10 meters)
Length Cu:   0    (units 1 meter)
Vendor Name: BROCADE         
Vendor OUI:  00:05:1e
Vendor PN:   57-0000088-01   
Vendor Rev:  A   
Wavelength:  850  (units nm)
Options:     003a Loss_of_Sig,Tx_Fault,Tx_Disable
BR Max:      0   
BR Min:      0   
Serial No:   HAF6184100018PB
Date Code:   181010  
DD Type:     0x68
Enh Options: 0xfa
Status/Ctrl: 0x0
Pwr On Time: 1.64 years (14349 hours)
E-Wrap Control: 0
O-Wrap Control: 0
Alarm flags[0,1] = 0x5, 0x0
Warn Flags[0,1] = 0x5, 0x0
Temperature: 51      Centigrade
Current:     7.508   mAmps
Voltage:     3272.9  mVolts
RX Power:    -8.1    dBm (155.8uW)
TX Power:    -3.0    dBm (500.6 uW)

 

CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support