Skip to main content
NetApp Knowledge Base

Unable to switchback following a motherboard replacement

Views:
70
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
metrocluster
Last Updated:

Applies to

  • AFF & FAS
  • ONTAP 9
  • Two-node stretch MetroCluster

Issue

  • Unable to perform a switchback after completing a motherboard replacement:
 
clusterA::> metrocluster switchback -simulate
[Job 001] Setting up the node and cluster components for the switchback operation...[Job 001] Job failed: Failed to set up the node and cluster components for the switchback operation. Use the
"metrocluster operation show" command to view detailed error information. Resolve the errors, then try the command
again.
clusterA::> metrocluster operation show
       Operation: switchback-simulate
           State: failed
      Start Time: 10/27/2022 11:34:27
        End Time: 10/27/2022 11:35:09
          Errors: Failed to set up the node and cluster components for the switchback operation.
                  clusterA (fatal): Configuration replication service is not ready in cluster "clusterB". Wait a few minutes, then try the command again.
 
  • The impaired node doesn't recognize its in switchover:
 
clusterB::> metrocluster show
Configuration: stretch
Cluster                        Entry Name             State
------------------------------ ---------------------- ---------------------
Local: clusterB
                                 Configuration State  configured
                                                Mode  normal
                                 AUSO Failure Domain  auso-on-cluster-disaster
Remote: clusterA
                                 Configuration State  configured
                                                Mode  switchover
                                 AUSO Failure Domain  auso-on-cluster-disaster
 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.

 