Issue

  • ONTAP node became disconnected on two target ports; no target side troubleshooting has impacted the state
  • Ports have experienced credit loss and subsequent resets with increasing frequency in the last few months.
  • Issue gets temporarily fixed, when a node reboot is performed. 
Examples:
 
Switch:
CHASSIS, WARNING, BrocadeG610,  Link Reset on Port S0,P2(19) vc_no=0 crd(s)lost=6 auto trigger.
 
ONTAP:
fct_tpd_work_thread_0: scsitarget.ispfct.cttimeout:debug]: FC HBA 0e nport 2031 timed out while transmitting common transport frame of type 0x1 and command code GIEL.
fct_tpd_work_thread_0: scsitarget.ispfct.cttimeout:debug]: FC HBA 0e nport 2031 timed out while transmitting common transport frame of type 0x1 and command code GFN.
fct_tpd_work_thread_0: scsitarget.ispfct.linkBreak:error]: Link break detected on Fibre Channel target adapter 0e. Firmware status code status1 0x2, status2 0x7, and status4 0x0.
fct_tpd_work_thread_0: scsitarget.ispfct.cttimeout:debug]: FC HBA 0f nport 2044 timed out while transmitting common transport frame of type 0x1 and command code RFT_ID.
fct_tpd_work_thread_0: scsitarget.ispfct.linkBreak:error]: Link break detected on Fibre Channel target adapter 0f. Firmware status code status1 0x2, status2 0x7, and status4 0x0.
fct_tpd_work_thread_0: fcp.io.status:debug]: STIO Adapter:0e AEN 0x8048 (RECV_ERROR) MboxStatus1 0x1022 MboxStatus2 0xa1
fct_tpd_work_thread_0: fcp.io.status:debug]: STIO Adapter:0e AEN 0x8048 (RECV_ERROR) MboxStatus1 0xfffe MboxStatus2 0x2

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.