Skip to main content
NetApp Knowledge Base

E-series dual controller in lockdown state with 0E LU

Views:
310
Visibility:
Public
Votes:
0
Category:
e-series-systems
Specialty:
esg
Last Updated:

Applies to

SANtricity OS 11.60.2

Issue

  • After drive replacement, E-series dual controller goes into lockdown state with 0E LU.
  • Major event log show errors below:
6/21/2022 11:47 Informational Controller Shelf 99, Bay B Internal configuration database read or write operation failed 11044 6005 0/0/0 Internal B
6/21/2022 11:47 Critical Drive Shelf 1, Bay 4 Assigned drive or hot spare-in use drive removed 11042 226D 0/0/0 Failure A
6/21/2022 11:44 Informational Drive Shelf 99, Bay 3 Drive marked removed 11028 2231 0/0/0 Internal B
6/21/2022 11:44 Critical Drive Shelf 99, Bay 3 Assigned drive or hot spare-in use drive removed 11022 226D 0/0/0 Failure B

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.