Answer

What are the default cluster network ports for each platform?

Check Active IQ if this impacts your systems

  • The following tables list the default cluster network ports for each storage platform model
  • Additional configurations are listed in NetApp Hardware Universe.
  • Verify supported connections for your platform and ONTAP version with the NetApp Hardware Universe
    • Select Platform > ONTAP version >  Show Results > Supported Connections
  • For MetroCluster configurations, see the MetroCluster Documentation
Default cluster network ports for AFF Platforms
AFF Platform Two ports Four Ports  Installation and Setup Instructions
AFF A900 e4a, e4b
NIC: X91153A (40/100GbE)
See HWU AFF A900 Installation
AFF A800
AFF C800
e0a, e1a See HWU AFF A800 Installation
AFF C800 Installation
AFF A700 e4a, e4b
NIC: X91440A (40GbE)
See HWU AFF A700 Installation
AFF A700s e0a, e0f e0a, e0b, e0f, e0g AFF A700s Installation
AFF A400 e3a, e3b
NIC: X1151A (40/100GbE)
e2a, e2b, e2c, e2d
NIC: X1147A (10GbE)
AFF A400 Installation
AFF C400 e0c, e0d e2a, e2b, e2c, e2d
NIC: X1147A (10GbE)
AFF C400 Installation
AFF A320 e0a, e0d N/A AFF A320 Installation
AFF A300 e0a, e0b e0a, e0b, e2a, e2b
NIC: X1117A-R6
AFF A300 Installation
AFF A250
AFF C250
e0c, e0d N/A AFF A250 Installation
AFF C400 Installation
AFF A220 e0a, e0b N/A AFF A220 Installation
AFF A150 e0a, e0b N/A AFF A150 Installation
AFF8020, AFF8040, AFF8060, AFF8080 e0a, e0c
(Minimum)
e0a, e0b, e0c, e0d
(Recommended)
AFF8020 Installation
AFF80x0 Installation
AFF80x0 with I/O Expansion Modules Installation
Default cluster network ports for FAS Platforms
FAS Platform Two Ports Four Ports Installation and Setup Instructions
FAS9500 e4a, e4b
NIC: X91153A (40/100GbE)
See HWU FAS9500 Installation
FAS9000 e4a, e4b
NIC: X91440A (40GbE)
See HWU FAS9000 Installation
FAS8700 e0c, e0d e2a, e2b, e2c, e2d
NIC: X1147A (10GbE)
FAS8700 Installation
FAS8300 e0c, e0d e2a, e2b, e2c, e2d
NIC: X1147A (10GbE)
FAS8300 Installation
FAS8200 e0a, e0b e0a, e0b, e2a, e2b
NIC: X1117A-R6
FAS8200 Installation
FAS500f e0c, e0d N/A FAS500f Installation
FAS2750, FAS2720 e0a, e0b N/A FAS2700 Installation
FAS2650, FAS2620 e0a, e0b N/A FAS2600 Installation
FAS8020, FAS8040, FAS8060, FAS8080 e0a, e0c e0a, e0b, e0c, e0d FAS8020 Installation
FAS80x0 Installation
FAS80x0 with I/O Expansion Modules Installation
FAS2552, FAS2554 e0e, e0f N/A FAS2552 Installation
FAS2554 Installation
FAS2520 e0d, e0f (10GBASE-T) N/A FAS2520 Installation
NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.