Skip to main content
NetApp Knowledge Base

No compression savings in ONTAP 9.8P1

Views:
2,223
Visibility:
Public
Votes:
1
Category:
ontap-9
Specialty:
core
Last Updated:

Applies to

  • ONTAP  9.8
  • Temperature Sensitive Storage Efficiency (TSSE)

Issue

  • All volumes with adaptive inline compression enabled display 0B compression in ONTAP 9.8:

::*> aggr show-efficiency -aggregate !*root,!*snaplock -fields volume-compression-saved
aggregate              volume-compression-saved
---------------------- ------------------------
aggr1                  0B
aggr2                  0B
aggr3                  0B
aggr4                  0B
 
  • Volume shows deduplication savings, but no space saved by compression:
::*> volume show -volume vol* -fields dedupe-space-saved,dedupe-space-saved-percent,compression-space-saved,compression-space-saved-percent

vserver  volume               dedupe-space-saved dedupe-space-saved-percent compression-space-saved compression-space-saved-percent
-------- -------------------- ------------------ -------------------------- ----------------------- -------------------------------
svm1     vol1                 120.9GB            51%                        0B                      0%                                
svm1     vol2                 22.69MB            0%                         0B                      0%
svm1     vol3                 111.6GB            7%                         0B                      0%
svm1     vol4                 184.2GB            10%                        0B                      0%
svm1     vol5                 24.50GB            70%                        0B                      0%
5 entries were displayed. 
  • Attempt to run compression manually fails with error: 
::*> volume efficiency start -vserver svm1 -volume vol1 -dedupe true -compression true -compaction true -scan-old-data true

Warning: This operation scans all of the data in volume "vol1" of Vserver "svm1". It might take a significant time, and degrade performance during that time. 
Do you want to continue? {y|n}: y  

Error: command failed: Failed to start efficiency on volume "vol1" of Vserver "svm1": "-compression" option is not supported on
                                     auto-adaptive compression enabled volumes.

 