In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.
NetApp Knowledge Base

How to calculate the neccesary volume size with the specified inode number

Views:
524
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
core
Last Updated:

Applies to

  • ONTAP 9
  • Cloud Volumes ONTAP(CVO)

Description

Below error message can be found when trying to change the Inode number to a specific number.

Example:

cluster::> df -i
Filesystem      iused   ifree    %iused    Mounted on     Vserver
/vol/Share01/   2027    21249099 0%        /Share01       svm_01

cluster::> vol show
Vserver   Volume       Aggregate    State      Type Size       Available  Used%
--------- ------------ ------------ ---------- ---- ---------- ---------- -----
svm_01    Share01      aggr1        online     RW   100GB      94.85GB    0%

cluster::> vol modify -volume Share01 -files 42502252

Error: command failed: Unable to set volume attribute "files" for volume "Share01" on Vserver "svm_01".
Reason: The value you entered(42502252) is invalid; maximum inode count cannot exceed 24903679.
Cannot support more than one inode per 4 KB of disk space.

 

Scan to view the article on your device
CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support