Conversion to FlexGroup fails with " Volume has invalid on-disk flags or options" error
Applies to
- ONTAP 9
- FlexGroup
- 7-mode transitioned FlexVol volumes with
nosnapandnosnapdiroptions set toon
Issue
- Conversion to FlexGroup fails with
Volume has invalid on-disk flags or optionserror:
::> set adv::*> volume conversion start -vserver vs1 -volume vol1 -foreground trueError: [Job 26893] Job failed: Volume conversion failed. Reason: Internal Error: Volume has invalid on-disk flags or options.- Starting in ONTAP 9.10.1, the error message was changed to the following:
::> set adv::*> volume conversion start -vserver vs1 -volume vol1
Error: command failed: [Job 233788] Job failed: Volume conversion failed. Reason: Volume with DSID 8029 cannot be converted to a FlexGroup volume because its configuration is not supported by FlexGroup volumes. Contact technical support
for further assistance.
vol convert failed with diag priority