Skip to main content
NetApp Knowledge Base

Brocade switch port down

Views:
76
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

Applies to

  • MetroCluster FC
  • ONTAP 9
  • Brocade Fibre Channel switch

Issue

  • An AutoSupport is received stating that a switch port is down.
  • switchshow output shows the port in No_Sync state:
Index Port Address  Media Speed   State       Proto
==================================================
17      17   071100   id    16G     No_Sync     FC
  • sfpshow output shows the SFP in the affected port has low RX value:
RX Power:    -4.9    dBm (324.9uW)
TX Power:    -2.7    dBm (534.0 uW)
  • The cluster node port connected to the switch port shows as down in sysconfig -a:

slot 10: FC Host Adapter 10c (QLogic 8324 rev. 2, N-port, <OFFLINE (hard)>)

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.