  • ATTO FibreBridge 7500N/7600N

Issue

  • storage bridge show -name ATTO_XXXXXXXXXXXXXXXX displays:

BridgeStatus: error

BridgeError Description List: ATTO_XXXXXXXXXXXXXXXX(XXXXXXXXXXXXXXXX):FC_PORT_1 is Offline.

  • Bridge dumpconfig output shows the FC port as down and data rate and connection mode show as N/A:

; Port    Status

;===============

1     Down

2     Up

FC1 DataRate         = N/A

FC1Connection Mode   = N/A

  • The dumpconfig also shows that the RX is low:

getFCSFPPower all

FC SFPinformation for port 1:

Tx power: 700.0uW

Rx power: 120.0uW

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.

 