Apply failed for Object: cifs_lug_local_group_db_view_DR - Reason: duplicate entry
Applies to
- MetroCluster
- ONTAP 9
- DR Config Replication failure
Issue
- An autosupport is triggered titled DR CONFIGURATION REPLICATION FAILED
metrocluster vserver show
displays an error
Example:
Cluster : ClusterA
Vserver : SVM1
Partner Vserver : SVM1-mc
Configuration State : syncing
Stream Status : processing-task
Failed Row : Table Name: cifs_lug_local_group_db_view_DR, Operation: get, Fields: SVM1-mc VSID SID AD-Group-Name - - Members
Failed Reason : Apply failed for Object: cifs_lug_local_group_db_view_DR Method: baseline. Reason: duplicate entry
Last apply fail time : 3/29/2020 12:25:41