Skip to main content
NetApp Knowledge Base

Nblade.CifsOperationTimedOut for SMB2_COM_SESSION_SETUP operation

Views:
44
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
nas
Last Updated:

Applies to

  • ONTAP 9
  • CIFS

Issue

  • ONTAP EMS events are generated for timed out CIFS operations
Example:
[node1:Nblade.CifsOperationTimedOut:error]: Detected a timed out CIFS operation. SMB command for this operation: SMB2_COM_SESSION_SETUP, Number of times this command was suspended: 1, Number of times this command was restarted: 0, Last CSM error during this operation: CSM_OK, Remote blade UUID: 00000000-0000-0000-0000-000000000000, Is QoS enabled: QoS_disabled, Last nBlade error during this operation: SPINNP_NO_FO_ERROR, Client IP address: 10.16.5.123, Local IP address: 10.16.6.123, Target Vserver ID: 1, Target disk's DSID: 0, Target Vserver Name: svm1
 
  • SECD log reports another thread is still in domain discovery and waits for 42 seconds

Example:[000.000.282] ERR : RESULT_ERROR_SECD_IN_DISCOVERY:6938 in lock() at src/utils/secd_lock_maps.cpp:109
[000.000.291] ERR : RESULT_ERROR_SECD_IN_DISCOVERY:6938 in reserveServer() at src/server_discovery/secd_service_list.cpp:1873
[000.000.300] ERR : RESULT_ERROR_GENERAL_INVALID_PTR:4 in unlock() at src/include/secd_lock_utils.h:130
[000.000.306] debug: Another thread is doing discovery for vserver 1 in reserveServer() at src/server_discovery/secd_service_list.cpp:1940 }
[042.255.631] debug: Created service key: 0000000e.office.lottery.co.at.MS_NETLOGON { in makeServiceKey() at src/server_discovery/secd_service_list.cpp:186 }
[042.275.284] CRIT : _maxConnectionSem held for 42 seconds for cache ref ID 1448140603, conn type NetLogon { in semaphoreReleased() at src/include/secd_thread_data_manager.h:219 }

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.