Node boots to loader when it halted with -power-off true with no error output
Applies to
ONTAP 9
Issue
- Halt two nodes to loader and confirmed both power status are off:
Cluster::> system halt -node * -inhibit-takeover true -skip-lif-migration-before-shutdown true -power-off true
Warning: Are you sure you want to power off node "Cluster-01"?
{y|n}: y
Warning: Are you sure you want to power off node "Cluster-02"?
{y|n}: y
2 entries were acted on.
BMC> system power status
Host power is off
- After node reboots, it boot to loader even if autoboot is enabled, and console log have no error output:
LOADER-A> printenv
Variable Name Value
-------------------- --------------------------------------------------
ARCH X86_64
AUTOBOOT true
AUTOBOOT_FROM PRIMARY
- Console have no error output, node can be normal boot up from loader via
boot_ontap
:
Wait BMC self-test result.
BMC self-test: OK.
UPI initialization.
CPU initialization.
Running full memory initialization.
CPU reset.
BIOS Version: 16.6
PEI start.
CPU PEI initialization.
Wait BMC self-test result.
BMC self-test: OK.
UPI initialization.
CPU initialization.
Running full memory initialization.
SPI FLASH: Primary BIOS
PEI end.
DXE start.
USB initialization.
PCI host bridge initialization.
CSM initialization.
PCI Bus initialization start.
BDS start.
Console output devices connect.
Version 2.20.1276. Copyright (C) 2021 American Megatrends, Inc.
BIOS Date: 09/15/2021 14:57:57 Ver: 16.6
Press <DEL> or <ESC> to enter setup.
Press <F7> to enter Boot Menu.
[System Information]
CPU = 2 Processors
DetectedCPU 0 : Intel(R) Xeon(R) Silver 4210 CPU @ 2.20GHz
Core : 10CPU 1 : Intel(R) Xeon(R) Silver 4210 CPU @ 2.20GHz
Core : 10Memory Size : 147456 MB
Ready to boot.
Boot Loader version 6.4.12
Copyright (C) 2000-2003 Broadcom Corporation.
Portions Copyright (C) 2002-2021 NetApp, Inc. All Rights Reserved.
ACPI RSDP Found at 0x6cc33000
LOADER-A> boot_ontap