CONTAP-37601: In a two-node stretch or fabric-attached MetroCluster configuration, AUSO might be disabled after an ONTAP upgrade
Issue
- In a two-node stretch or fabric-attached MetroCluster configuration automatic unplanned switchover (AUSO) might be disabled after an ONTAP upgrade.
*Verify on both clusters that AUSO is enabled on all nodes after the ONTAP upgrade. If AUSO is
disabled, enable it manually:Cluster_A::> set advanced
Cluster_A::*> metrocluster node show -fields automatic-uso
dr-group-id cluster node automatic-uso
----------- ------------ --------------- -------------
1 ClusterA ClusterA-01 true
1 ClusterA ClusterA-02 true
1 ClusterB ClusterB-01 false <<<<<<<<<<<<
1 ClusterB ClusterB-02 true