Skip to main content
NetApp Knowledge Base

Targets not visible in Fabric MetroCluster

Views:
160
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

Applies to

  • ONTAP 9
  • Fabric MetroCluster
  • Stretched MetroCluster
  • X1133A: Broadcom LPE16004; Quad-Port 16Gb FC Adapter (PCIe)

Issue

  • Targets are missing from HBA Host adapter(s) and the connected switch port reports '?' which transtitioned the system into Multi-pah HA rather than Quad-path HA.
Example:

::> system node run -node <node> sysconfig -a

slot 2: FC Host Adapter 2d (Emulex XE201 rev. 48, N-port, <UP>)
    Board name:        111-02451
    Serial Number:     0000000000
    Firmware rev:      12.0.378.1
    Host Port Id:      0x00000
    FC Node Name:      2:000:000000:000000
    FC Port Name:      1:000:000000:000000
    SFP Vendor:        EMULEX
    SFP Part Number:   AFBR-57F5MZ-ELX
    SFP Serial Number: XXXXXXXXXXX
    SFP Capabilities:  4, 8 or 16 Gbit
    Link Data Rate:    16 Gbit
    Switch Port:       ?
    [disks, shelves & ATTO bridges missing]

  • ATTO FibreBridge metadata is missing:

Example:

	slot 2: FC Host Adapter 2c (Emulex XE201 rev. 48, N-port, <UP>)
		Board name:        111-02451
		Serial Number:     0000000000
		Firmware rev:      12.0.378.1
		Host Port Id:      0x00000
		FC Node Name:      2:000:000000:000000
		FC Port Name:      1:000:000000:000000
		SFP Vendor:        EMULEX
		SFP Part Number:   AFBR-57F5MZ-ELX
		SFP Serial Number: XXXXXXXXXXX
		SFP Capabilities:  4, 8 or 16 Gbit
		Link Data Rate:    16 Gbit
		Switch Port:       FC-SW-1:3
...
[Removed disks to shorten output]
...
                FC-SW-1:7.126L0               : ???????? ???????????????? ????  FB7500N000000
                FC-SW-3:7.126L0               : ???????? ???????????????? ????  FB7500N000000
		FC-SW-1:7.shelf20      : DS224-12  Firmware rev. IOM12 A: 0281  IOM12 B: 0281
  • Replacement of SFP on the node end or on the switch end does not change the status of the port. 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.