SwitchFanNotPresent_Alert False Alert
Applies to
- MetroClusterIP
- ONTAP 9
- Cisco
Issue
SwitchFanNotPresent_Alert
raised and cleared after a period of time:
Tue Nov 05 03:38:11 +0300 [Node02: cshmd: hm.alert.raised:alert]: Alert Id = SwitchFanNotPresent_Alert , Alerting Resource = Switch1(FOC000000)/Fan Module-1 raised by monitor ethernet-switch
Tue Nov 05 05:01:37 +0300 [Node02: cshmd: hm.alert.cleared:notice]: Alert Id =SwitchFanNotPresent_Alert , Alerting Resource = Switch1(FOC000000)/Fan Module-1 cleared by monitor ethernet-switch
Switch Fan showing as ok
`show environment`
Fan:
---------------------------------------------------------------------------
Fan Model Hw Direction Status
---------------------------------------------------------------------------
Fan1(sys_fan1) NXA-FAN-30CFM-F 0.0 front-to-back Ok
Fan2(sys_fan2) NXA-FAN-30CFM-F 0.0 front-to-back Ok
Fan3(sys_fan3) NXA-FAN-30CFM-F 0.0 front-to-back Ok
Fan4(sys_fan4) NXA-FAN-30CFM-F 0.0 front-to-back Ok
Fan_in_PS1 N2200-PAC-400W -- front-to-back Ok
Fan_in_PS2 N2200-PAC-400W -- front-to-back Ok
Fan Zone Speed: Zone 1: 0x32
Fan Air Filter : NotSupported