Issue
Subsystems 'MetroCluster' and 'FHM-Switch' reports degraded due to "FabricSwitchUnreachable_Alert" in MCC-IP cluster
::> system health alert show
Node: Node-n3
Alert ID: FabricSwitchUnreachable_Alert
Resource: Brocade_XX.YYY.ZZ.38
Severity: Major
Indication Time: Sat Feb 15 11:37:14 2025
Suppress: false
Acknowledge: false
Probable Cause: "Brocade_XX.YYY.ZZ.38" switch is not reachable over
the management network.
Possible Effect: Switch "Brocade_XX.YYY.ZZ.38" cannot be monitored for
alerts.
Corrective Actions: 1) Ensure that the node management LIF is up by using the command "network interface show".
2) Ensure that the switch "Brocade_XX.YYY.ZZ.38" is alive by using the command "network ping".
3) Ensure that the switch is reachable over SNMP by
checking its SNMP settings after logging into the
switch.