Skip to main content
NetApp Knowledge Base

StorageFCAdapterFault_Alert - Resolution Guide

Views:
263
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
MetroCluster
Last Updated:

Applies to

  • ONTAP 9
  • MetroCluster Fibre Channel
  • StorageFCAdapterFault_Alert

Description

StorageFCAdapterFault_Alerts are triggered on FC MetroCluster systems when an initiator link is detected at being down. This alert can have multiple causes.

  • Call home alert:

[mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process nchm: StorageFCAdapterFault_Alert [100000109bxxxxxx].

  • The MetroCluster_Node subsystem health reports degraded:

cluster::> system health subsystem show
Subsystem         Health
----------------- ------------------
SAS-connect       ok
Environment       ok
Memory            ok
Service-Processor ok
Switch-Health     ok
CIFS-NDO          ok
Motherboard       ok
IO                ok
MetroCluster      ok
MetroCluster_Node degraded
FHM-Switch        ok
FHM-Bridge        ok
SAS-connect_Cluster
                  ok
13 entries were displayed.

  • Health alert reports the adapter(s) at fault:

cluster::> system health alert show
               Node: node-01
           Resource: 4d
           Severity: Major
    Indication Time: Sat Aug 15 13:05:58 2020
           Suppress: false
        Acknowledge: false
     Probable Cause: FC initiator adapter 4d is at fault.
    Possible Effect: Resiliency of backend storage is compromised.
 Corrective Actions: 1. Ensure that the FC initiator link has not been tampered with.
                     2. Verify the operational status of the FC initiator
                     adapter by using the command "system node run -node
                     local -command storage show adapter".

  • Event logs report:

::> event log show

[slifc_intrd: fci.link.break:error]: Link break detected on Fibre Channel adapter 4d.
[slifc_timeout_3: fci.link.error:error]: Could not recover link on Fibre Channel adapter 4d after 30 seconds. Taking the adapter offline.
[nchmd: hm.alert.raised:alert]: Alert Id = StorageFCAdapterFault_Alert , Alerting Resource = 100000109bxxxxxx raised by monitor node-connect

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.